Literature DB >> 22502764

Novel use of an exchange catheter to facilitate intubation with an Aintree catheter in a tall patient with a predicted difficult airway: a case report.

Shaun E Gruenbaum1, Benjamin F Gruenbaum, Sergey Tsaregorodtsev, Michael Dubilet, Israel Melamed, Alexander Zlotnik.   

Abstract

INTRODUCTION: The Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) has been shown to successfully facilitate difficult intubations when other methods have failed. The Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) has a fixed length of 56 cm, and it has been suggested in the literature that it may be too short for safe use in patients who are tall. CASE
PRESENTATION: We present the case of a 32-year-old, 180 cm tall Caucasian woman with a predicted difficult airway who presented to our facility for an emergency cesarean section. After several failed intubation attempts via direct laryngoscopy, an airway was established with a laryngeal mask airway. After delivery of a healthy baby, our patient's condition necessitated tracheal intubation. A fiber-optic bronchoscope loaded with an Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) was passed through the laryngeal mask airway into the trachea until just above the carina, but was too short to safely allow for the passage of an endotracheal tube.
CONCLUSIONS: We present a novel technique in which the Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) was replaced with a longer (100 cm) exchange catheter, over which an endotracheal tube was passed successfully into the trachea.

Entities:  

Year:  2012        PMID: 22502764      PMCID: PMC3353199          DOI: 10.1186/1752-1947-6-108

Source DB:  PubMed          Journal:  J Med Case Rep        ISSN: 1752-1947


  15 in total

1.  Introducer catheter for fiberoptic intubation does exist.

Authors:  Lloyd Craker; Bruce Allan; Michael Lim
Journal:  Anesth Analg       Date:  2006-01       Impact factor: 5.108

2.  Successful reintubation after cervical spine exposure using an Aintree intubation catheter and a Laryngeal Mask Airway.

Authors:  Rafi Avitsian; D John Doyle; Robert Helfand; Andrew Zura; Ehab Farag
Journal:  J Clin Anesth       Date:  2006-05       Impact factor: 9.452

3.  Tracheal intubation via the Classic and Proseal laryngeal mask airways: a manikin study using the Aintree Intubating Catheter.

Authors:  E J Blair; R Mihai; T M Cook
Journal:  Anaesthesia       Date:  2007-04       Impact factor: 6.955

4.  Non-conventional uses of the Aintree Intubating Catheter in management of the difficult airway.

Authors:  T M Cook; C Seller; K Gupta; M Thornton; E O'Sullivan
Journal:  Anaesthesia       Date:  2007-02       Impact factor: 6.955

5.  A response to 'low-skill fibreoptic intubation: use of the Aintree catheter with the classic LMA'.

Authors:  R Menzies; C Frerk
Journal:  Anaesthesia       Date:  2006-03       Impact factor: 6.955

6.  Failure of the classic LMA and Aintree catheter with bronchoscope for tracheal intubation while performing manual inline stabilisation.

Authors:  K B Greenland; G Pang; A E Donaldson; M W Frouws
Journal:  Anaesth Intensive Care       Date:  2008-03       Impact factor: 1.669

Review 7.  Laryngeal mask airway and the ASA difficult airway algorithm.

Authors:  J L Benumof
Journal:  Anesthesiology       Date:  1996-03       Impact factor: 7.892

8.  A ventilation-exchange bougie for fibreoptic intubations with the laryngeal mask airway.

Authors:  D P Atherton; E O'Sullivan; D Lowe; P Charters
Journal:  Anaesthesia       Date:  1996-12       Impact factor: 6.955

9.  Use of the Aintree intubation catheter in a patient with an unexpected difficult airway.

Authors:  Andrew Zura; D John Doyle; Marc Orlandi
Journal:  Can J Anaesth       Date:  2005 Jun-Jul       Impact factor: 5.063

10.  Airway management in a 980-lb patient: use of the Aintree intubation catheter.

Authors:  D John Doyle; Andrew Zura; Mangalakaraipudur Ramachandran; Jia Lin; Jacek B Cywinski; Brian Parker; Theodore Marks; Marc Feldman; Robert R Lorenz
Journal:  J Clin Anesth       Date:  2007-08       Impact factor: 9.452

View more
  3 in total

1.  Challenges with tracheal tube exchange using a flexible bronchoscope and an Aintree Intubation Catheter.

Authors:  G I James; D Williams
Journal:  Anaesth Rep       Date:  2021-06-09

2.  Obstetric Anaesthetists' Association and Difficult Airway Society guidelines for the management of difficult and failed tracheal intubation in obstetrics.

Authors:  M C Mushambi; S M Kinsella; M Popat; H Swales; K K Ramaswamy; A L Winton; A C Quinn
Journal:  Anaesthesia       Date:  2015-11       Impact factor: 6.955

3.  Characteristics of a New Device for Intubation Through a Laryngeal Mask Airway Over a Flexible Endoscope.

Authors:  Vernon H Vivian; Tyson L Pardon; Samuel Vivian; André Van Zundert
Journal:  Med Devices (Auckl)       Date:  2021-07-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.