Literature DB >> 22499839

Monitoring peri-therapeutic cerebral circulation time: a feasibility study using color-coded quantitative DSA in patients with steno-occlusive arterial disease.

C J Lin1, S C Hung, W Y Guo, F C Chang, C B Luo, J Beilner, M Kowarschik, W F Chu, C Y Chang.   

Abstract

BACKGROUND AND
PURPOSE: Intracranial hemodynamics are important for management of SOAD. This study aimed to monitor peri-stent placement intracranial CirT of patients with SOAD.
MATERIALS AND METHODS: Twenty-five patients received stent placement for extracranial ICA stenosis, and 34 patients with normal CirT were recruited as controls. Their color-coded DSAs were used to define the Tmax of selected intravascular ROI. A total of 20 ROIs of the ICA, OphA, ACA, MCA, FV, PV, OV, SSS, SS, IJV, and MCV were selected. rTmax was defined as the Tmax at the selected region of interest minus Tmax at the cervical segment of the ICA (I1 on AP view and IA on lateral view). rTmax of the PV was defined as intracranial CirT. Intergroup and intragroup longitudinal comparisons of rTmax were performed.
RESULTS: rTmax values of the normal cohorts were as follows: ICA-AP, 0.12; ICA-LAT, 0.10; A1, 0.28; A2, 0.53; A3, 0.81; M1, 0.40; M2, 0.80; M3, 0.95; OphA, 0.35; FV, 4.83; PV, 5.11; OV, 5.17; SSS, 6.16; SS, 6.51; IJV, 6.81; and MCV, 3.86 seconds. Before stent placement, the rTmax values of arterial ROIs, except A3 and M3, were prolonged compared with values from control subjects (P < .05). None of the rTmax of any venous ROIs in the stenotic group was prolonged with significance. After stent placement, the rTmax of all arterial ROIs shortened significantly, except A1and M3. Poststenting rTmax was not different from the control group.
CONCLUSIONS: Without extra contrast medium and radiation dosages, color-coded quantitative DSA enables real-time monitoring of peri-therapeutic intracranial CirT in patients with SOAD .

Entities:  

Mesh:

Year:  2012        PMID: 22499839      PMCID: PMC7964755          DOI: 10.3174/ajnr.A3049

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  28 in total

1.  Adaptive changes of autoregulation in chronic cerebral hypotension with arteriovenous malformations: an acetazolamide-enhanced single-photon emission CT study.

Authors:  L Hacein-Bey; R Nour; J Pile-Spellman; R Van Heertum; P D Esser; W L Young
Journal:  AJNR Am J Neuroradiol       Date:  1995-10       Impact factor: 3.825

Review 2.  [Value of CT and MR angiography for diagnostics of intracranial aneurysms].

Authors:  C Roth
Journal:  Radiologe       Date:  2011-02       Impact factor: 0.635

Review 3.  Sub-Nyquist acquisition and constrained reconstruction in time resolved angiography.

Authors:  Charles A Mistretta
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

4.  Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model.

Authors:  Tobias Struffert; Sabine Ott; Edyta Adamek; Marc Schwarz; Tobias Engelhorn; Stephan Kloska; Yu Deuerling-Zheng; Arnd Doerfler
Journal:  Eur Radiol       Date:  2011-03-02       Impact factor: 5.315

5.  Intraprocedural changes in angiographic cerebral circulation time predict cerebral blood flow after carotid artery stenting.

Authors:  Hiroshi Aikawa; Kiyoshi Kazekawa; Masanori Tsutsumi; Masanari Onizuka; Minoru Iko; Tomonobu Kodama; Kouhei Nii; Shuko Hamaguchi; Hosei Etou; Kimiya Sakamoto
Journal:  Neurol Med Chir (Tokyo)       Date:  2010       Impact factor: 1.742

6.  Computer computations of cardiac output using the gamma function.

Authors:  C F Starmer; D O Clark
Journal:  J Appl Physiol       Date:  1970-02       Impact factor: 3.531

7.  Flat detector CT in the evaluation of brain parenchyma, intracranial vasculature, and cerebral blood volume: a pilot study in patients with acute symptoms of cerebral ischemia.

Authors:  T Struffert; Y Deuerling-Zheng; S Kloska; T Engelhorn; C M Strother; W A Kalender; M Köhrmann; S Schwab; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2010-04-08       Impact factor: 3.825

8.  Poststenotic flow and intracranial hemodynamics in patients with carotid stenosis: transoral carotid ultrasonography study.

Authors:  Masahiro Kamouchi; Kazuhiro Kishikawa; Yasushi Okada; Tooru Inoue; Setsuro Ibayashi; Mitsuo Iida
Journal:  AJNR Am J Neuroradiol       Date:  2005-01       Impact factor: 3.825

9.  Evaluation of the functional diffusion map as an early biomarker of time-to-progression and overall survival in high-grade glioma.

Authors:  Daniel A Hamstra; Thomas L Chenevert; Bradford A Moffat; Timothy D Johnson; Charles R Meyer; Suresh K Mukherji; Douglas J Quint; Stephen S Gebarski; Xiaoying Fan; Christina I Tsien; Theodore S Lawrence; Larry Junck; Alnawaz Rehemtulla; Brian D Ross
Journal:  Proc Natl Acad Sci U S A       Date:  2005-11-02       Impact factor: 11.205

10.  Brain imaging with a flat detector C-arm : Technique and clinical interest of XperCT.

Authors:  M Söderman; D Babic; S Holmin; T Andersson
Journal:  Neuroradiology       Date:  2008-06-17       Impact factor: 2.804

View more
  28 in total

1.  Real-Time, In Vivo Monitoring, and Quantitative Assessment of Intra-Arterial Vasospasm Therapy.

Authors:  Philipp Gölitz; Iris Kaschka; Stefan Lang; Karl Roessler; Frauke Knossalla; Arnd Doerfler
Journal:  Neurocrit Care       Date:  2016-08       Impact factor: 3.210

2.  Changes of time-attenuation curve blood flow parameters in patients with and without carotid stenosis.

Authors:  C-J Lin; F-C Chang; W-Y Guo; S-C Hung; C-B Luo; J Beilner; M Kowarschik; W-F Chu
Journal:  AJNR Am J Neuroradiol       Date:  2015-02-26       Impact factor: 3.825

3.  Can iterative reconstruction improve imaging quality for lower radiation CT perfusion? Initial experience.

Authors:  C J Lin; T H Wu; C H Lin; S C Hung; C F Chiu; M-J Liu; M M H Teng; F C Chang; W Y Guo; C Y Chang
Journal:  AJNR Am J Neuroradiol       Date:  2013-04-11       Impact factor: 3.825

4.  Quantitative evaluation of arteriovenous malformation hemodynamic changes after endovascular treatment using parametric color coding: A case series study.

Authors:  Rodrigo Rivera; Juan G Sordo; Daniel Echeverria; Lautaro Badilla; Camila Pinto; Catalina Merino-Osorio
Journal:  Interv Neuroradiol       Date:  2017-08-01       Impact factor: 1.610

5.  Cerebral circulation time derived from fMRI signals in large blood vessels.

Authors:  Jinxia Fiona Yao; James H Wang; Ho-Ching Shawn Yang; Zhenhu Liang; Aaron A Cohen-Gadol; Vitaliy L Rayz; Yunjie Tong
Journal:  J Magn Reson Imaging       Date:  2019-04-29       Impact factor: 4.813

6.  Intracranial contrast transit times on digital subtraction angiography decrease more in patients with delayed intraparenchymal hemorrhage after Pipeline.

Authors:  Denise Brunozzi; Sophia F Shakur; Fady T Charbel; Ali Alaraj
Journal:  Interv Neuroradiol       Date:  2017-12-12       Impact factor: 1.610

7.  Ultra-early Detection of Microcirculatory Injury as Predictor of Developing Delayed Cerebral Ischemia After Aneurysmal Subarachnoid Hemorrhage.

Authors:  Philipp Gölitz; Philip Hoelter; Julie Rösch; Karl Roessler; Frauke Knossalla; Arnd Doerfler
Journal:  Clin Neuroradiol       Date:  2017-08-15       Impact factor: 3.649

8.  Color-coded digital subtraction angiography in the management of a rare case of middle cerebral artery pure arterial malformation. A technical and case report.

Authors:  Caleb E Feliciano; Eva Pamias-Portalatin; Jorge Mendoza-Torres; Euclides Effio; Yadira Moran; Rafael Rodriguez-Mercado
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

9.  Intracranial venous hemodynamics and rupture of cerebral aneurysm.

Authors:  Kwo-Whei Lee; Fong-Y Tsai; Wei-Liang Chen; Chi-Kuang Liu; Chen-Ling Kuo
Journal:  Neuroradiol J       Date:  2014-12-01

10.  Stenotic transverse sinus predisposes to poststenting hyperperfusion syndrome as evidenced by quantitative analysis of peritherapeutic cerebral circulation time.

Authors:  C-J Lin; F-C Chang; F-Y Tsai; W-Y Guo; S-C Hung; D Y-T Chen; C-H Lin; C-Y Chang
Journal:  AJNR Am J Neuroradiol       Date:  2014-01-16       Impact factor: 3.825

View more