Literature DB >> 22499803

Wide sternal retraction may impede internal mammary artery graft flow and reduce myocardial function during off-pump coronary artery bypass grafting: presentation of two cases.

Andreas Espinoza1, Jacob Bergsland, Runar Lundblad, Erik Fosse.   

Abstract

The internal mammary artery (IMA) is routinely used for grafting of the left anterior descending coronary artery (LAD), providing good flow to the anterior left ventricle (LV) wall. Impeded IMA-to-LAD flow may result in myocardial ischaemia and haemodynamic deterioration. From a study population, we describe two incidents where myocardial ischaemia was observed during off-pump coronary artery bypass surgery (CABG), with a confirmed reduction in the IMA-to-LAD flow in one patient. In patient no. 1, normal IMA flow was assessed by transit-time flow measurement after a complete IMA-to-LAD anastomosis. The anterior LV wall thickening was monitored continuously by epicardial ultrasonic transducers. Normal wall thickening was confirmed after IMA grafting. During a wide sternal opening for circumflex grafting the anterior wall motion displayed an ischaemic pattern, with reduced systolic and increased post-systolic wall thickening. IMA flow was reduced simultaneously. When easing the sternal opening, IMA flow normalized, as did the motion pattern in the anterior LV wall. In patient no. 2, similar changes in wall thickening occurred during a wide sternal opening after IMA-to-LAD grafting. When easing the retractor, the wall thickening normalized. It is important for the surgeon to be aware of this possible cause of myocardial ischaemia, with a risk of subsequent haemodynamic deterioration. This may not only be of great importance during off-pump CABG, but can also be significant for successful weaning from the cardiopulmonary bypass machine.

Entities:  

Mesh:

Year:  2012        PMID: 22499803      PMCID: PMC3380999          DOI: 10.1093/icvts/ivs135

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  13 in total

1.  Conversion to cardiopulmonary bypass in off-pump coronary artery bypass grafting: its effect on outcome.

Authors:  P Soltoski; T Salerno; L Levinsky; S Schmid; S Hasnain; T Diesfeld; C Huang; M Akhter; O Alnoweiser; J Bergsland
Journal:  J Card Surg       Date:  1998 Sep-Oct       Impact factor: 1.620

Review 2.  Technical tips and pitfalls in OPCAB surgery: the buffalo experience.

Authors:  J Bergsland; G D'Ancona; H Karamanoukian; M Ricci; S Schmid; T A Salerno
Journal:  Heart Surg Forum       Date:  2000       Impact factor: 0.676

3.  Role of coronary graft flow measurement during reoperations for early graft failure after off-pump coronary revascularization.

Authors:  M Ricci; H L Karamanoukian; T A Salerno; G Dancona; J Bergsland
Journal:  J Card Surg       Date:  1999 Sep-Oct       Impact factor: 1.620

Review 4.  An update on internal mammary artery grafting for coronary artery disease.

Authors:  Sune Damgaard; Daniel A Steinbrüchel; Henrik K Kjaergard
Journal:  Curr Opin Cardiol       Date:  2005-11       Impact factor: 2.161

5.  Significant improvement in flow through a potential internal mammary graft after partial approximation of the sternum.

Authors:  J E Graham; M Peter; J Mathai
Journal:  J Thorac Cardiovasc Surg       Date:  1984-09       Impact factor: 5.209

6.  Quantification of left ventricular systolic function by tissue Doppler echocardiography: added value of measuring pre- and postejection velocities in ischemic myocardium.

Authors:  Thor Edvardsen; Stig Urheim; Helge Skulstad; Kjetil Steine; Halfdan Ihlen; Otto A Smiseth
Journal:  Circulation       Date:  2002-04-30       Impact factor: 29.690

7.  Detection of ischemia and new insight into left ventricular physiology by strain Doppler and tissue velocity imaging: assessment during coronary bypass operation of the beating heart.

Authors:  Helge Skulstad; Kai Andersen; Thor Edvardsen; Kjell Arne Rein; Tor Inge Tønnessen; Per Kristian Hol; Erik Fosse; Halfdan Ihlen
Journal:  J Am Soc Echocardiogr       Date:  2004-12       Impact factor: 5.251

8.  Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting.

Authors:  G D'Ancona; H L Karamanoukian; M Ricci; S Schmid; J Bergsland; T A Salerno
Journal:  Eur J Cardiothorac Surg       Date:  2000-03       Impact factor: 4.191

9.  Intracoronary shunt prevents ischemia in off-pump coronary artery bypass surgery.

Authors:  Jacob Bergsland; Per Snorre Lingaas; Helge Skulstad; Per Kristian Hol; Per Steinar Halvorsen; Rune Andersen; Milada Småstuen; Runar Lundblad; Jan Svennevig; Kai Andersen; Erik Fosse
Journal:  Ann Thorac Surg       Date:  2009-01       Impact factor: 4.330

10.  Conversions in off-pump coronary surgery.

Authors:  Emir Mujanovic; Emir Kabil; Mehdin Hadziselimovic; Muniba Softic; Azur Azabagic; Jacob Bergsland
Journal:  Heart Surg Forum       Date:  2003       Impact factor: 0.676

View more
  2 in total

1.  eComment. Extended sternal retraction and internal mammarian artery flow.

Authors:  Ahmet H Arslan; Murat Ugurlucan; Yahya Yildiz; Sertac Cicek
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-07

Review 2.  Anesthetic management of off-pump simultaneous coronary artery bypass grafting and lobectomy: Case report and literature review.

Authors:  Xian Zhao; Yuhong Li; Hai-Ying Kong; Lin Zhang; Xiao-Hong Wen
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.