Literature DB >> 22495899

Reliability of two-dimensional transvaginal sonographic measurement of lower uterine segment thickness using video sequences.

Amélie Boutin1, Nicole Jastrow, Mario Girard, Stéphanie Roberge, Nils Chaillet, Normand Brassard, Emmanuel Bujold.   

Abstract

OBJECTIVES: To report the intra- and interobserver reliability of measurement of the lower uterine segment (LUS) thickness using transvaginal sonographic videos.
METHODS: A prospective study of 60 women with previous, low-transverse cesarean undergoing LUS examination (36 to 39 weeks) was performed. Two observers independently measured full LUS thickness using transvaginal sonography. A video of the LUS was recorded and analyzed more than 2 months later by both observers. Intra- and interobserver reliability was assessed with median absolute differences and interquartile range (IQR), nonparametric limits of agreement, intraclass correlation coefficients (ICC) with 95% confidence interval (95% CI), and kappa coefficients.
RESULTS: Median full LUS thickness was 3.6 mm (range: 0.9 to 8.0 mm). Intraobserver repeatability was excellent (median difference: 0.2 mm, IQR: 0.1 to 0.4; ICC: 0.94, 95% CI: 0.90 to 0.96; kappa: 1.00). Interobserver (median difference: 0.3 mm, IQR: 0.2 to 1.3; ICC: 0.91, 95% CI: 0.86 to 0.95; kappa: 0.76, 95% CI: 0.54 to 0.98) and intermethod reproducibility (median difference: 0.4 mm, IQR: 0.2 to 0.8; ICC: 0.82, 95% CI: 0.72 to 0.89; kappa: 0.69, 95% CI: 0.43 to 0.94) were good. However, both interobserver and intermethod reproducibility were improved when LUS thickness was below 3 mm.
CONCLUSION: Full LUS thickness measured from transvaginal sonographic videos has excellent intra- and interobserver reproducibility and good reproducibility with live transvaginal ultrasound.
Copyright © 2012 by Thieme Medical Publishers

Entities:  

Mesh:

Year:  2012        PMID: 22495899     DOI: 10.1055/s-0032-1310524

Source DB:  PubMed          Journal:  Am J Perinatol        ISSN: 0735-1631            Impact factor:   1.862


  3 in total

1.  Intrapartum ultrasound measurement of the lower uterine segment thickness in parturients with previous scar in labor: a cross-sectional study.

Authors:  Shahla K Alalaf; Tarek Mohamed M Mansour; Sileem Ahmad Sileem; Nazar P Shabila
Journal:  BMC Pregnancy Childbirth       Date:  2022-05-14       Impact factor: 3.105

2.  A simplified cervix model in response to induction balloon in pre-labour.

Authors:  James Andrew Smith
Journal:  Theor Biol Med Model       Date:  2013-09-26       Impact factor: 2.432

3.  A cluster-randomized trial to reduce major perinatal morbidity among women with one prior cesarean delivery in Québec (PRISMA trial): study protocol for a randomized controlled trial.

Authors:  N Chaillet; E Bujold; B Masse; W A Grobman; P Rozenberg; J C Pasquier; A Shorten; M Johri; F Beaudoin; H Abenhaim; S Demers; W Fraser; M Dugas; S Blouin; E Dubé; R Gauthier
Journal:  Trials       Date:  2017-09-20       Impact factor: 2.279

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.