Literature DB >> 22493630

Classification of Metastatic versus Non-Metastatic Axillary Nodes in Breast Cancer Patients: Value of Cortex-Hilum Area Ratio with Ultrasound.

Sung Eun Song1, Bo Kyoung Seo, Seung Hwa Lee, Ann Yie, Ki Yeol Lee, Kyu Ran Cho, Ok Hee Woo, Sang Hoon Cha, Baek Hyun Kim.   

Abstract

PURPOSE: To investigate the significance of the cortex-hilum (CH) area ratio and longitudinal-transverse (LT) axis ratio and the blood flow pattern for diagnosis of metastatic axillary lymph nodes by ultrasound in breast cancer patients.
METHODS: From October 2005 to July 2006, we prospectively evaluated axillary nodes with ultrasound in 205 consecutive patients who had category 4B, 4C or 5 breast lesions according to the Breast Imaging Reporting and Data System-Ultrasound (BI-RADS-Ultrasound®). Among the 205, there were 24 patients who had pathologic verification of breast cancer and axillary lymph node status. For a total of 80 axillary nodes we measured the areas of the cortex and hilum of lymph nodes and calculated the area ratio. We also measured the length of the longitudinal and transverse axis of the lymph nodes and calculated the length ratio. We evaluated the blood flow pattern on power Doppler imaging and classified each lymph node into a central or peripheral pattern. Diagnostic performance was analyzed according to positive criteria for lymph node metastasis (CH area ratio >2, LT axis ratio <2, peripheral type on power Doppler imaging).
RESULTS: The sensitivity of the CH area ratio was superior to that of the LT axis ratio (94.1% vs. 82.3%, p=0.031) and to that of the blood flow pattern (94.1% vs. 29.4%, p=0.009). For specificity, all three evaluating parameters had high values (89.1-95.6%) and no significant differences were found (p=0.121). The CH area ratio had a better positive predictive value than the LT axis ratio (94.1% vs. 80.0%, p=0.030) and power Doppler imaging (94.1% vs. 66.6%, p=0.028). For the negative predictive value, the CH area ratio was superior to the LT axis ratio (95.6% vs. 86.6%, p=0.035) and the blood flow pattern (95.6% vs. 63.0%, p=0.027).
CONCLUSION: We recommend the CH area ratio of an axillary lymph node on ultrasound as a quantitative indicator for the classification of lymph nodes. The CH area ratio can improve diagnostic performance when compared with the LT axis ratio or blood flow pattern.

Entities:  

Keywords:  Breast; Lymph nodes; Lymphatic metastasis; Ultrasonography

Year:  2012        PMID: 22493630      PMCID: PMC3318176          DOI: 10.4048/jbc.2012.15.1.65

Source DB:  PubMed          Journal:  J Breast Cancer        ISSN: 1738-6756            Impact factor:   3.588


  21 in total

Review 1.  Imaging of axillary lymph nodes.

Authors:  A Lernevall
Journal:  Acta Oncol       Date:  2000       Impact factor: 4.089

2.  Preoperative breast cancer staging: MR imaging of the axilla with ultrasmall superparamagnetic iron oxide enhancement.

Authors:  Sven C A Michel; Thomas M Keller; Johannes M Fröhlich; Daniel Fink; Rosmarie Caduff; Burkhardt Seifert; Borut Marincek; Rahel A Kubik-Huch
Journal:  Radiology       Date:  2002-11       Impact factor: 11.105

Review 3.  US-guided core needle biopsy of axillary lymph nodes in patients with breast cancer: why and how to do it.

Authors:  Hiroyuki Abe; Robert A Schmidt; Charlene A Sennett; Akiko Shimauchi; Gillian M Newstead
Journal:  Radiographics       Date:  2007-10       Impact factor: 5.333

4.  Sentinel-lymph-node biopsy for breast cancer--not yet the standard of care.

Authors:  K M McMasters; A E Giuliano; M I Ross; D S Reintgen; K K Hunt; D R Byrd; V S Klimberg; P W Whitworth; L C Tafra; M J Edwards
Journal:  N Engl J Med       Date:  1998-10-01       Impact factor: 91.245

5.  Multicentre study of ultrasonographically guided axillary node biopsy in patients with breast cancer.

Authors:  A Y de Kanter; C H van Eijck; A N van Geel; R H Kruijt; S C Henzen; M A Paul; A M Eggermont; T Wiggers
Journal:  Br J Surg       Date:  1999-11       Impact factor: 6.939

6.  Benign and malignant breast masses and axillary nodes: evaluation with echo-enhanced color power Doppler US.

Authors:  W T Yang; C Metreweli; P K Lam; J Chang
Journal:  Radiology       Date:  2001-09       Impact factor: 11.105

7.  Sentinel lymph node biopsy with metastasis: can axillary dissection be avoided in some patients with breast cancer?

Authors:  C Reynolds; R Mick; J H Donohue; C S Grant; D R Farley; L S Callans; S G Orel; G L Keeney; T J Lawton; B J Czerniecki
Journal:  J Clin Oncol       Date:  1999-06       Impact factor: 44.544

8.  The evolving role of axillary lymph node fine-needle aspiration in the management of carcinoma of the breast.

Authors:  Martin C Chang; Pavel Crystal; Terence J Colgan
Journal:  Cancer Cytopathol       Date:  2011-03-22       Impact factor: 5.284

9.  Gray scale and power Doppler US in the preoperative evaluation of axillary metastases in breast cancer patients with no palpable lymph nodes.

Authors:  Gul Esen; Bengi Gurses; Mehmet Halit Yilmaz; Sennur Ilvan; Sila Ulus; Varol Celik; Mehmet Farahmand; Ozden Oz Calay
Journal:  Eur Radiol       Date:  2005-02-03       Impact factor: 5.315

10.  Clinical evaluation of axillar lymph nodes compared to surgical and pathological findings.

Authors:  R A Sacre
Journal:  Eur J Surg Oncol       Date:  1986-06       Impact factor: 4.424

View more
  1 in total

1.  Comparative study between ultrasound-guided fine needle aspiration cytology of axillary lymph nodes and sentinel lymph node histopathology in early-stage breast cancer.

Authors:  Lívio Portela Cardoso-Coelho; Rafael Soares Borges; Airlane Pereira Alencar; Larysse Maira Cardoso-Campos-Verdes; João Paulo da Silva-Sampaio; Umbelina Soares Borges; Luiz Henrique Gebrim; Benedito Borges da Silva
Journal:  Oncol Lett       Date:  2017-03-07       Impact factor: 2.967

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.