Literature DB >> 22492450

Low-temperature decontamination with hydrogen peroxide or chlorine dioxide for space applications.

T Pottage1, S Macken, K Giri, J T Walker, A M Bennett.   

Abstract

The currently used microbial decontamination method for spacecraft and components uses dry-heat microbial reduction at temperatures of >110°C for extended periods to prevent the contamination of extraplanetary destinations. This process is effective and reproducible, but it is also long and costly and precludes the use of heat-labile materials. The need for an alternative to dry-heat microbial reduction has been identified by space agencies. Investigations assessing the biological efficacy of two gaseous decontamination technologies, vapor hydrogen peroxide (Steris) and chlorine dioxide (ClorDiSys), were undertaken in a 20-m(3) exposure chamber. Five spore-forming Bacillus spp. were exposed on stainless steel coupons to vaporized hydrogen peroxide and chlorine dioxide gas. Exposure for 20 min to vapor hydrogen peroxide resulted in 6- and 5-log reductions in the recovery of Bacillus atrophaeus and Geobacillus stearothermophilus, respectively. However, in comparison, chlorine dioxide required an exposure period of 60 min to reduce both B. atrophaeus and G. stearothermophilus by 5 logs. Of the three other Bacillus spp. tested, Bacillus thuringiensis proved the most resistant to hydrogen peroxide and chlorine dioxide with D values of 175.4 s and 6.6 h, respectively. Both low-temperature decontamination technologies proved effective at reducing the Bacillus spp. tested within the exposure ranges by over 5 logs, with the exception of B. thuringiensis, which was more resistant to both technologies. These results indicate that a review of the indicator organism choice and loading could provide a more appropriate and realistic challenge for the sterilization procedures used in the space industry.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22492450      PMCID: PMC3370535          DOI: 10.1128/AEM.07948-11

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  33 in total

1.  Oligophilic bacteria as tools to monitor aseptic pharmaceutical production units.

Authors:  P P Nagarkar; S D Ravetkar; M G Watve
Journal:  Appl Environ Microbiol       Date:  2001-03       Impact factor: 4.792

2.  Procedures necessary for the prevention of planetary contamination.

Authors:  L B Hall; C W Bruch
Journal:  Life Sci Space Res       Date:  1965

3.  Vapor-phase hydrogen peroxide as a surface decontaminant and sterilant.

Authors:  N A Klapes; D Vesley
Journal:  Appl Environ Microbiol       Date:  1990-02       Impact factor: 4.792

4.  Biological indicators for low temperature steam and formaldehyde sterilization: the effect of defined media on sporulation, growth index and formaldehyde resistance of spores of Bacillus stearothermophilus strains.

Authors:  A M Wright; E V Hoxey; C J Soper; D J Davies
Journal:  J Appl Bacteriol       Date:  1995-10

5.  Variation in quantitative respirator fit factors due to fluctuations in leak size during fit testing.

Authors:  U Krishnan; K Willeke; A Juozaitis; T Myojo; G Talaska; R Shukla
Journal:  Am Ind Hyg Assoc J       Date:  1994-04

6.  Systematic evaluation of the efficacy of chlorine dioxide in decontamination of building interior surfaces contaminated with anthrax spores.

Authors:  Vipin K Rastogi; Shawn P Ryan; Lalena Wallace; Lisa S Smith; Saumil S Shah; G Blair Martin
Journal:  Appl Environ Microbiol       Date:  2010-03-19       Impact factor: 4.792

7.  Recurrent isolation of hydrogen peroxide-resistant spores of Bacillus pumilus from a spacecraft assembly facility.

Authors:  Michael J Kempf; Fei Chen; Roger Kern; Kasthuri Venkateswaran
Journal:  Astrobiology       Date:  2005-06       Impact factor: 4.335

8.  The ability of airborne Klebsiella pneumoniae to colonize mouse lungs.

Authors:  N J Bolister; H E Johnson; C M Wathes
Journal:  Epidemiol Infect       Date:  1992-08       Impact factor: 2.451

9.  Bacillus nealsonii sp. nov., isolated from a spacecraft-assembly facility, whose spores are gamma-radiation resistant.

Authors:  Kasthuri Venkateswaran; Michael Kempf; Fei Chen; Masataka Satomi; Wayne Nicholson; Roger Kern
Journal:  Int J Syst Evol Microbiol       Date:  2003-01       Impact factor: 2.747

10.  Decontamination of Bacillus thuringiensis spores on selected surfaces by chlorine dioxide gas.

Authors:  Y Han; Bruce Applegate; R H Linton; P E Nelson
Journal:  J Environ Health       Date:  2003-11       Impact factor: 1.179

View more
  9 in total

1.  Low-cost, Small-scale Decontamination of Laboratory Equipment by Using Chlorine Dioxide Gas.

Authors:  Cara M Mitchell; Alison McGrath; Breanne Beck; Michael J Schurr; Derek Fong; Jorik K Leszczynski; Christopher A Manuel
Journal:  J Am Assoc Lab Anim Sci       Date:  2019-08-29       Impact factor: 1.232

2.  Examination of Material Compatibilities with Ionized and Vaporized Hydrogen Peroxide Decontamination.

Authors:  Tohru Kimura; Hiroyuki Yahata; Yoshimichi Uchiyama
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-09-17       Impact factor: 1.232

3.  Kinetics of Inactivation of Bacillus subtilis subsp. niger Spores and Staphylococcus albus on Paper by Chlorine Dioxide Gas in an Enclosed Space.

Authors:  Tao Wang; Jinhui Wu; Jiancheng Qi; Limei Hao; Ying Yi; Zongxing Zhang
Journal:  Appl Environ Microbiol       Date:  2016-05-02       Impact factor: 4.792

4.  Inactivation of Escherichia coli Cells in Aqueous Solution by Atmospheric-Pressure N2, He, Air, and O2 Microplasmas.

Authors:  Renwu Zhou; Xianhui Zhang; Zhenhua Bi; Zichao Zong; Jinhai Niu; Ying Song; Dongping Liu; Size Yang
Journal:  Appl Environ Microbiol       Date:  2015-05-29       Impact factor: 4.792

Review 5.  Review of Decontamination Techniques for the Inactivation of Bacillus anthracis and Other Spore-Forming Bacteria Associated with Building or Outdoor Materials.

Authors:  Joseph P Wood; Alden Charles Adrion
Journal:  Environ Sci Technol       Date:  2019-04-02       Impact factor: 9.028

6.  MS2 virus inactivation by atmospheric-pressure cold plasma using different gas carriers and power levels.

Authors:  Yan Wu; Yongdong Liang; Kai Wei; Wei Li; Maosheng Yao; Jue Zhang; Sergey A Grinshpun
Journal:  Appl Environ Microbiol       Date:  2014-11-21       Impact factor: 4.792

7.  Plasma-Activated Aerosolized Hydrogen Peroxide (aHP) in Surface Inactivation Procedures.

Authors:  Camille Freyssenet; Stéphane Karlen
Journal:  Appl Biosaf       Date:  2019-03-01

8.  Utilization of low-pressure plasma to inactivate bacterial spores on stainless steel screws.

Authors:  Katharina Stapelmann; Marcel Fiebrandt; Marina Raguse; Peter Awakowicz; Günther Reitz; Ralf Moeller
Journal:  Astrobiology       Date:  2013-06-14       Impact factor: 4.335

9.  Analysis of SteraMist ionized hydrogen peroxide technology in the sterilization of N95 respirators and other PPE.

Authors:  Avilash K Cramer; Deborah Plana; Helen Yang; Peter K Sorger; Nicole R LeBoeuf; Mary M Carmack; Enze Tian; Michael S Sinha; David Krikorian; David Turner; Jinhan Mo; Ju Li; Rajiv Gupta; Heather Manning; Florence T Bourgeois; Sherry H Yu
Journal:  Sci Rep       Date:  2021-01-21       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.