Literature DB >> 22492337

Test method for empirically determining inertial properties of manual wheelchairs.

Matthew R Eicholtz1, Jayme J Caspall, Phuc V Dao, Stephen Sprigle, Al Ferri.   

Abstract

The iMachine is a spring-loaded turntable used to measure inertial properties of irregularly shaped rigid bodies, specifically manual wheelchairs. We used a Newton-Euler approach to calculate wheelchair mass and center of mass (CM) location from static force measurements using load cells. We determined the moment of inertia about the vertical axis from the natural frequency of the system in simple harmonic motion. The device was calibrated to eliminate the effects of platform components on measurement error. For objects with known inertial properties, the average relative error of the mass and the CM coordinates (x and y) were 0.76%, 0.89%, and 1.99%, respectively. The resolution of the moment of inertia calculation depends on the ratio of test piece inertia to system inertia, such that the higher the ratio, the more accurate the measurements. We conducted a Gage Repeatability and Reproducibility (Gage R&R) test using three manual wheelchairs measured three times by three operators; the results showed that over 90% of the variance in inertia was caused by differences in the wheelchairs being measured. Gage R&R analysis indicated that measurement system operation was acceptable using criteria from the Automobile Industry Action Group for both inertia and mass measurements.

Entities:  

Mesh:

Year:  2012        PMID: 22492337     DOI: 10.1682/jrrd.2011.03.0045

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  4 in total

1.  Modeling manual wheelchair propulsion cost during straight and curvilinear trajectories.

Authors:  Jacob Misch; Morris Huang; Stephen Sprigle
Journal:  PLoS One       Date:  2020-06-18       Impact factor: 3.240

2.  Inertial and frictional influences of instrumented wheelchair wheels.

Authors:  Stephen Sprigle; Morris Huang; Jui-Te Lin
Journal:  J Rehabil Assist Technol Eng       Date:  2016-06-20

3.  Spinal cord injury and pressure ulcer prevention: using functional activity in pressure relief.

Authors:  May Stinson; Rachel Schofield; Cathy Gillan; Julie Morton; Evie Gardner; Stephen Sprigle; Alison Porter-Armstrong
Journal:  Nurs Res Pract       Date:  2013-04-09

Review 4.  Aspects of manual wheelchair configuration affecting mobility: a review.

Authors:  Fausto Orsi Medola; Valeria Meirelles Carril Elui; Carla da Silva Santana; Carlos Alberto Fortulan
Journal:  J Phys Ther Sci       Date:  2014-02-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.