Positron emission tomographic study of auditory sensation in a patient with a cochlear implant.

J Ito1, J Sakakibara, I Honjo, Y Iwasaki, Y Yonekura.   

Abstract

The speech comprehension ability of patients with a cochlear implant is fairly good even when information from the implant device is insufficient. It is presumed that the higher brain system has important roles in discriminating speech. The purpose of the present study was to investigate the function of the auditory cortices of a patient with a cochlear implant before and after sound signal inputs. In this study, we used positron emission computed tomography, which can detect brain activity by providing quantitative measurements of the metabolic rates of oxygen and glucose. Without sound signals, the auditory cortices of the patient showed remarkably low metabolic rates. However, with the cochlear implant device, the activity returned to near normal levels. These findings suggest that the activation of the speech comprehension mechanism of the higher brain system can be initiated by sound signals from the implant device.

Entities:  

Mesh:

Year:  1990        PMID: 2248748     DOI: 10.1001/archotol.1990.01870120083015

Source DB:  PubMed          Journal:  Arch Otolaryngol Head Neck Surg        ISSN: 0886-4470


  6 in total

1.  PET imaging of cochlear-implant and normal-hearing subjects listening to speech and nonspeech.

Authors:  D Wong; R T Miyamoto; D B Pisoni; M Sehgal; G D Hutchins
Journal:  Hear Res       Date:  1999-06       Impact factor: 3.208

2.  Cortical perfusion response to an electrical stimulation of the auditory nerve in profoundly deaf patients: study with technetium-99m hexamethylpropylene amine oxime single photon emission tomography.

Authors:  Y Le Scao; A Robier; J L Baulieu; P Beutter; L Pourcelot
Journal:  Eur J Nucl Med       Date:  1992

3.  Auditory cortical activation and plasticity after cochlear implantation measured by PET using fluorodeoxyglucose.

Authors:  Zuzanna Łukaszewicz-Moszyńska; Magdalena Lachowska; Kazimierz Niemczyk
Journal:  Funct Neurol       Date:  2014 Apr-Jun

4.  Positron emission tomography in cochlear implant and auditory brain stem implant recipients.

Authors:  R T Miyamoto; D Wong; D B Pisoni; G Hutchins; M Sehgal; R Fain
Journal:  Am J Otol       Date:  1999-09

5.  Decreased auditory GABA+ concentrations in presbycusis demonstrated by edited magnetic resonance spectroscopy.

Authors:  Fei Gao; Guangbin Wang; Wen Ma; Fuxin Ren; Muwei Li; Yuling Dong; Cheng Liu; Bo Liu; Xue Bai; Bin Zhao; Richard A E Edden
Journal:  Neuroimage       Date:  2014-11-15       Impact factor: 6.556

6.  Cochlear implants stimulate activity-dependent CREB pathway in the deaf auditory cortex: implications for molecular plasticity induced by neural prosthetic devices.

Authors:  Justin Tan; Sandra Widjaja; Jin Xu; Robert K Shepherd
Journal:  Cereb Cortex       Date:  2007-12-05       Impact factor: 5.357