Literature DB >> 22487270

Management of mandibular interforaminal fractures using 3 dimensional locking and standard titanium miniplates - a comparative preliminary report of 10 cases.

Manoj Kumar Jain1, K Sankar, C Ramesh, Ramakrishna Bhatta.   

Abstract

PURPOSE: The aim of this follow up clinical study was to compare and evaluate the effectiveness of 2mm 4 holed 3-dimensional (3D) locking titanium miniplates over standard miniplate fixation using Champy's technique in the management of interforaminal mandibular fractures. PATIENTS AND METHODS: A prospective randomized double blind clinical trial was carried out in patients with well defined inclusion and exclusion criteria. Patients were followed for a period of 2 months at the intervals of 1 week, 2 weeks, 4 weeks, 6 weeks and 2 months by a blinded senior oral surgeon for wound dehiscence, infection, postoperative occlusion, significant postoperative complications, need for post-operative inter maxillary fixation and radiological evaluation of reduction, fixation. RESULT: 10 patients were enrolled in both the groups in this preliminary report with no case of clinically significant postoperative complications. In comparison, 3D locking plates were economical, easy to adapt, required less operating time, and provided better stability. However, 2 patients in group 1 (3D locking plates) with severely displaced unfavourable fractures required 6 holed plates or more for adequate stability.
CONCLUSION: Because of its added advantages and encouraging results in comparison to standard miniplate, we suggest use of 3D 4 holed locking 2mm titanium miniplate for the management of isolated moderately displaced mandibular fractures in inter mental foramen region.
Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22487270     DOI: 10.1016/j.jcms.2012.03.007

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  5 in total

1.  Comparative Evaluation of 3d Locking Versus Non-Locking Titanium Miniplates in the Treatment of Mandibular Fracture.

Authors:  Mohsin Khan; Ashish Kumar; Tanya Khaitan; Dharmendra Kumar Sinha; Chandan Kumar
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2020-05-20

2.  Bite Force as a Parameter for Comparison Between Three-Dimensional and Standard Titanium Miniplates for the Management of Anterior Mandibular Fractures: A Prospective Randomized Double-Blinded Clinical Trial.

Authors:  Manoj Kumar Jain; Priyadarshini Kerur
Journal:  J Maxillofac Oral Surg       Date:  2018-02-09

3.  Evaluation of Efficacy of Three-dimensional Stainless Steel Mini-Plates in the Treatment of Fractures of the Mandible: A Prospective Study.

Authors:  Shreyas H Gupte; Shruti Chaddva; Yash Jethwani; Aditi Mohandas; Digvijay P Kumavat; Nirali Jhaveri
Journal:  J Orthop Case Rep       Date:  2016 Nov-Dec

4.  Three-dimensional versus standard miniplate, lag screws versus miniplates, locking plate versus non-locking miniplates: Management of mandibular fractures, a systematic review and meta-analysis.

Authors:  Patiguli Wusiman; Dilidaer Taxifulati; Li Weidong; Adili Moming
Journal:  J Dent Sci       Date:  2019-01-14       Impact factor: 2.080

5.  Three-dimensional Locking Plate and Conventional Miniplates in the Treatment of Mandibular Anterior Fractures.

Authors:  Nilima J Budhraja; Ramakrishna S Shenoi; Samprati J Badjate; Kshitij O Bang; Pranav D Ingole; Vrinda S Kolte
Journal:  Ann Maxillofac Surg       Date:  2018 Jan-Jun
  5 in total