Literature DB >> 22486234

Elemental determination of microsamples by liquid film dielectric barrier discharge atomic emission spectrometry.

Qian He1, Zhenli Zhu, Shenghong Hu, Hongtao Zheng, Lanlan Jin.   

Abstract

In this study, a new liquid-film dielectric barrier discharge (LFDBD) atomic emission source was developed for microsample elemental determination. It consists of a copper electrode, a tungsten wire electrode, and a piece of glass slide between them, which serves as the dielectric barrier as well as the sample plate. The sample solution with 1 mol L(-1) nitric acid, when deposited onto the surface of the glass slide, forms a thin liquid film. The plasma is generated between the tip of the tungsten wire electrode and the liquid film surface when alternating-current (ac) high voltage (peak voltage ~3.7 kV, frequency ~30 kHz) is applied on the electrodes. Qualitative and quantitative determinations of metal ions in the sample solution were achieved by atomic emission measurements in the plasma and were demonstrated in this study with elements Na, K, Cu, Zn, and Cd. Detection limits were in the range from 0.6 ng (7 μg L(-1)) for Na to 6 ng (79 μg L(-1)) for Zn. Repeatability, expressed as relative standard deviation from seven repetitive analyses of samples with analyte concentrations at 1 mg L(-1), varied from 2.1% to 4.4%. Compared with other liquid discharge systems that operate at atmospheric pressure, the current system offers several advantages: First, it eliminates the use of a sample flow system (e.g., syringe or peristaltic pump); instead, a small aliquot of sample is directly pipetted onto the glass slide for analysis. Second, it is a microanalysis system and requires sample volume ≤80 μL, a benefit when a limited amount of sample is available. Third, because the sample is applied in aliquot, there is no washout time, and the analysis can be easily extended to sample array for high-throughput analysis. The proposed LFDBD is promising for in-field elemental determination because of its simplicity, cost effectiveness, low power supply, and no inert gas requirement.

Entities:  

Year:  2012        PMID: 22486234     DOI: 10.1021/ac300518y

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  1 in total

1.  Matrix-Assisted Plasma Atomization Emission Spectrometry for Surface Sampling Elemental Analysis.

Authors:  Xin Yuan; Xuefang Zhan; Xuemei Li; Zhongjun Zhao; Yixiang Duan
Journal:  Sci Rep       Date:  2016-01-14       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.