Literature DB >> 2248618

Effect of hemodynamic factors on atherosclerosis in the abdominal aorta.

N D Nguyen1, A K Haque.   

Abstract

The distribution pattern of atherosclerotic plaques in the human abdominal aorta is examined using autopsy specimens. The location of the plaques is found to be dominant where flow separation may occur in the abdominal aorta based on hemodynamic theory. This observation provides strong support for the role of flow separation with subsequent platelet aggregation in atherogenesis. The severity of plaque formed in the anterior inferior wall of the abdominal aorta is found to be affected by the branching angles of the renal arteries as deduced from experimental results using glass tube models.

Entities:  

Mesh:

Year:  1990        PMID: 2248618     DOI: 10.1016/0021-9150(90)90005-4

Source DB:  PubMed          Journal:  Atherosclerosis        ISSN: 0021-9150            Impact factor:   5.162


  8 in total

1.  Distribution of abdominal aortic calcium by computed tomography: impact of analysis method on quantitative calcium score.

Authors:  Michael L Chuang; Richard W Leslie; Joseph M Massaro; Emily S Manders; Caroline S Fox; Udo Hoffmann; Christopher J O'Donnell
Journal:  Acad Radiol       Date:  2013-11       Impact factor: 3.173

2.  The renal artery ostium flow diverter: structure and potential role in atherosclerosis.

Authors:  Edward B Neufeld; Zu-Xi Yu; Danielle Springer; Qing Yu; Robert S Balaban
Journal:  Atherosclerosis       Date:  2010-01-28       Impact factor: 5.162

3.  Effects of the shape of coronary arteries on the presence, extent, and severity of their disease.

Authors:  Recep Demirbag; Remzi Yilmaz
Journal:  Heart Vessels       Date:  2005-09       Impact factor: 2.037

4.  Absence of atherosclerosis evolution in the coronary arterial segment covered by myocardial tissue in cholesterol-fed rabbits.

Authors:  Y Ishikawa; T Ishii; N Asuwa; S Masuda
Journal:  Virchows Arch       Date:  1997-02       Impact factor: 4.064

5.  A New Method for Quantifying Abdominal Aortic Wall Shear Stress Using Phase Contrast Magnetic Resonance Imaging and the Womersley Solution.

Authors:  Elizabeth Iffrig; Lucas H Timmins; Retta El Sayed; W Robert Taylor; John N Oshinski
Journal:  J Biomech Eng       Date:  2022-09-01       Impact factor: 1.899

6.  Hemodynamically driven stent strut design.

Authors:  Juan M Jiménez; Peter F Davies
Journal:  Ann Biomed Eng       Date:  2009-05-27       Impact factor: 3.934

7.  Influence of the renal artery ostium flow diverter on hemodynamics and atherogenesis.

Authors:  Scott Albert; Robert S Balaban; Edward B Neufeld; Jenn Stroud Rossmann
Journal:  J Biomech       Date:  2014-03-20       Impact factor: 2.712

8.  A case report: An aortobifemoral bypass implant found during cadaver dissection promotes inquiry-based learning.

Authors:  Zachary P Gotham; Rachel S Tanilli; Olivia M Wirfel; Prasad S Dalvi
Journal:  Int J Surg Case Rep       Date:  2020-07-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.