Literature DB >> 2248394

The inhibitory action of halothane on reflex constriction in mesenteric capacitance veins.

T A Stekiel1, K Ozono, J B McCallum, Z J Bosnjak, W J Stekiel, J P Kampine.   

Abstract

Potent inhalational anesthetics depress autonomic reflex responses at multiple sites. Most studies emphasize cardiac chronotropic changes and changes in systemic blood pressure. Recently, active reflex venoconstriction of 500-1,000 microns O.D. mesenteric veins has been demonstrated. In the current study, the effects of halothane on the reflex responses of similar mesenteric veins were measured. Mesenteric vein diameter and intravenous pressure were measured in 500-1,000 microns O.D. veins from the mesentery of segments of terminal ileum externalized in situ from 27 New Zealand white rabbits anesthetized with alpha-chloralose. Mean arterial pressure was measured with femoral arterial cannulation, and heart rate was determined from the arterial pressure signal. In a separate group of six animals, sympathetic efferent nerve activity was measured from a postganglionic splanchnic nerve. Reflex venoconstriction and increases in mean arterial pressure and mesenteric vein pressure in response to bilateral carotid occlusion were attenuated by 0.5% and 1% inhaled halothane but not by superfusate equilibrated with 3% halothane. Decreases in mesenteric vein diameter and increases in mesenteric vein pressure in response to celiac ganglion stimulation were unaffected by both 0.5% inhaled halothane and superfusate equilibrated with 5% halothane. The bilateral carotid occlusion reflex-mediated increase in sympathetic efferent nerve activity was depressed by both 0.5% and 1% inhaled halothane. The effect of inhaled halothane on prestimulation baseline vein diameter was inconsistent. Superfusate equilibrated with 5% but not 3% halothane caused baseline venodilation. These results suggest a mechanism whereby control of venous tone is inhibited by halothane proximal to the postganglionic neuron. This could involve central or ganglionic inhibition.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2248394     DOI: 10.1097/00000542-199012000-00015

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  2 in total

1.  Perioperative tissue thickness measurement by a new miniature ultrasound device.

Authors:  J Schumacher; W Eichler; O Bauer; K F Klotz
Journal:  J Clin Monit Comput       Date:  1998-12       Impact factor: 2.502

2.  Anesthesia-Associated Relative Hypovolemia: Mechanisms, Monitoring, and Treatment Considerations.

Authors:  Jessica Noel-Morgan; William W Muir
Journal:  Front Vet Sci       Date:  2018-03-16
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.