Literature DB >> 22483875

A test strip platform based on DNA-functionalized gold nanoparticles for on-site detection of mercury (II) ions.

Zhiyong Guo1, Jing Duan, Fei Yang, Min Li, Tingting Hao, Sui Wang, Danyi Wei.   

Abstract

A test strip, based on DNA-functionalized gold nanoparticles for Hg(2+) detection, has been developed, optimized and validated. The developed colorimetric mercury sensor system exhibited a highly sensitive and selective response to mercury. The measurement principle is based on thymine-Hg(2+)-thymine (T-Hg(2+)-T) coordination chemistry and streptavidin-biotin interaction. A biotin-labeled and thiolated DNA was immobilized on the gold nanoparticles (AuNPs) surface through a self-assembling method. Another thymine-rich DNA, which was introduced to form DNA duplexes on the AuNPs surface with thymine-Hg(2+)-thymine (T-Hg(2+)-T) coordination in the presence of Hg(2+), was immobilized on the nitrocellulose membrane as the test zone. When Hg(2+) ions were introduced into this system, they induced the two strands of DNA to intertwist by forming T-Hg(2+)-T bonds resulting in a red line at the test zone. The biotin-labeled and thiolated DNA-functionalized AuNPs could be captured by streptavidin which was immobilized on the nitrocellulose membrane as the control zone. Under optimized conditions, the detection limit for Hg(2+) was 3 nM, which is lower than the 10nM, maximum contaminant limit defined by the US Environmental Protection Agency (EPA) for drinking water. A parallel analysis of Hg(2+) in pool water samples using cold vapor atomic absorption spectrometry showed comparable results to those obtained from the strip test. Therefore, the results obtained in this study could be used as basic research for the development of Hg(2+) detection, and the method developed could be a potential on-site screening tool for the rapid detection of Hg(2+) in different water samples without special instrumentation. All experimental variables that influence the test strip response were optimized and reported.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22483875     DOI: 10.1016/j.talanta.2012.01.012

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Lateral flow test for visual detection of silver (I) based on cytosine-Ag(I)-cytosine interaction in C-rich oligonucleotides.

Authors:  Zebin Guo; Yafeng Zheng; Hui Xu; Baodong Zheng; Wanwei Qiu; Zebin Guo
Journal:  Mikrochim Acta       Date:  2017-08-24       Impact factor: 5.833

2.  Recombinant streptavidin fusion proteins as signal reporters in rapid test of human hepatitis C virus infection.

Authors:  Shengliang Zhou; Shinian Cao; Guoliang Ma; Tielin Ding; Jingjing Mu; Weilu Han; Dongxu Sun; Caifa Chen
Journal:  J Clin Lab Anal       Date:  2018-10-23       Impact factor: 2.352

Review 3.  Bio-Recognition in Spectroscopy-Based Biosensors for *Heavy Metals-Water and Waterborne Contamination Analysis.

Authors:  Alessandra Aloisi; Antonio Della Torre; Angelantonio De Benedetto; Rosaria Rinaldi
Journal:  Biosensors (Basel)       Date:  2019-07-30

4.  Development of a portable lab-on-a-valve device for making primary diagnoses based on gold-nanoparticle aggregation induced by a switchable linker.

Authors:  Jungwoo Hahn; Eunghee Kim; Hyebin Han; Young Jin Choi
Journal:  RSC Adv       Date:  2020-08-24       Impact factor: 4.036

5.  A relay strategy for the mercury (II) chemodosimeter with ultra-sensitivity as test strips.

Authors:  Zhijun Ruan; Conggang Li; Jian-Rong Li; Jingui Qin; Zhen Li
Journal:  Sci Rep       Date:  2015-11-06       Impact factor: 4.379

  5 in total