Literature DB >> 22482676

The biomechanical effect of torsion on humeral shaft repair techniques for completed pathological fractures.

Ahmed Al-Jahwari1, Emil H Schemitsch, Jay S Wunder, Peter C Ferguson, Rad Zdero.   

Abstract

In the presence of a tumor defect, completed humeral shaft fractures continue to be a major surgical challenge since there is no "gold standard" treatment. This is due, in part, to the fact that only one prior biomechanical study exists on the matter, but which only compared 2 repair methods. The current authors measured the humeral torsional performance of 5 fixation constructs for completed pathological fractures. In 40 artificial humeri, a 2-cm hemi-cylindrical cortical defect with a transverse fracture was created in the lateral cortex. Specimens were divided into 5 different constructs and tested in torsion. Construct A was a broad 10-hole 4.5-mm dynamic compression plate (DCP). Construct B was the same as A except that the screw holes and the tumor defect were filled with bone cement and the screws were inserted into soft cement. Construct C was the same as A except that the canal and tumor defect were filled with bone cement and the screws were inserted into dry cement. Construct D was a locked intramedullary nail inserted in the antegrade direction. Construct E was the same as D except that bone cement filled the defect. For torsional stiffness, construct C (4.45 ± 0.20 Nm/deg) was not different than B or E (p > 0.16), but was higher than A and D (p < 0.001). For failure torque, construct C achieved a higher failure torque (69.65 ± 5.35 Nm) than other groups (p < 0.001). For the failure angle, there were no differences between plating constructs A to C (p ≥ 0.11), except for B versus C (p < 0.05), or between nailing groups D versus E (p = 0.97), however, all plating groups had smaller failure angles than both nailing groups (p < 0.05). For failure energy, construct C (17.97 ± 3.59 J) had a higher value than other groups (p < 0.005), except for A (p = 0.057). Torsional failure always occurred in the bone in the classic "spiral" pattern. Construct C provided the highest torsional stability for a completed pathological humeral shaft fracture.

Entities:  

Mesh:

Year:  2012        PMID: 22482676     DOI: 10.1115/1.4005696

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  4 in total

1.  Indications for prophylactic osteosynthesis associated with curettage in benign and low-grade malignant primitive bone tumors of the distal femur in adult patients: a case series.

Authors:  Carlo Perisano; Carlo Barone; Daniele Stomeo; Giulio Di Giacomo; Michele Vasso; Alfredo Schiavone Panni; Giulio Maccauro
Journal:  J Orthop Traumatol       Date:  2016-07-09

Review 2.  The Applications of Finite Element Analysis in Proximal Humeral Fractures.

Authors:  Yongyu Ye; Wei You; Weimin Zhu; Jiaming Cui; Kang Chen; Daping Wang
Journal:  Comput Math Methods Med       Date:  2017-09-10       Impact factor: 2.238

3.  Treatment of pathological fractures of the long bones.

Authors:  Julie J Willeumier; Yvette M van der Linden; Michiel A J van de Sande; P D Sander Dijkstra
Journal:  EFORT Open Rev       Date:  2017-03-13

4.  Survival Prediction in Patients Treated Surgically for Metastases of the Appendicular Skeleton-An External Validation of 2013-SPRING Model.

Authors:  Maria Anna Smolle; Ewald Musser; Marko Bergovec; Joerg Friesenbichler; Christine Linda Wibmer; Lukas Leitner; Michala Skovlund Sørensen; Michael Mørk Petersen; Iva Brcic; Joanna Szkandera; Susanne Scheipl; Andreas Leithner
Journal:  Cancers (Basel)       Date:  2022-07-20       Impact factor: 6.575