Stent-grafting of thoracic aortic diseases has developed as an alternative therapeutic modality in thoracic aneurysm management. Postprocedural complications include mortality, endoleaks, paraplegia and stroke. Other complications that may arise in cases of overstenting the origin of the left subclavian arther include left upper limb ischemia, subclavian steal syndrome and stroke. Posterior circulation strokes due to vertebral artery insufficiency have been reported in the past. In the present case, a fatal stroke caused by a cerebellar infarct culminating in the death of a patient with a leaking thoracic aortic aneurysm is reported. Medical personnel as well as patients should be aware of this possible complication. Vigilance in assessing the contralateral cerebral circulation before the procedure is a prerequisite in less acute circumstances.

Entities:  

Keywords:  Aneurysm; Endovascular; Stroke; Thoracic

Year:  2008        PMID: 22477374      PMCID: PMC2728375          DOI: 10.1055/s-0031-1278282

Source DB:  PubMed          Journal:  Int J Angiol        ISSN: 1061-1711


  5 in total

1.  Endovascular stent-graft management of thoracic aortic diseases.

Authors:  M D Dake
Journal:  Eur J Radiol       Date:  2001-07       Impact factor: 3.528

Review 2.  Complications of thoracic aortic endografts: spinal cord ischemia and stroke.

Authors:  Timothy M Sullivan; Thoralf M Sundt
Journal:  J Vasc Surg       Date:  2006-02       Impact factor: 4.268

3.  Endovascular repair of descending thoracic aortic aneurysms: an early experience with intermediate-term follow-up.

Authors:  R Greenberg; T Resch; U Nyman; M Lindh; J Brunkwall; P Brunkwall; M Malina; B Koul; B Lindblad; K Ivancev
Journal:  J Vasc Surg       Date:  2000-01       Impact factor: 4.268

4.  Intentional occlusion of the left subclavian artery during stent-graft implantation in the thoracic aorta: risk and relevance.

Authors:  Tim C Rehders; Michael Petzsch; Huseyin Ince; Stephan Kische; Thomas Korber; Dietmar H Koschyk; Tushar Chatterjee; Frank Weber; Christoph A Nienaber
Journal:  J Endovasc Ther       Date:  2004-12       Impact factor: 3.487

5.  Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs.

Authors:  Johannes Görich; Yahia Asquan; Harald Seifarth; Stefan Krämer; Xaver Kapfer; Karl-Heinz Orend; Ludger Sunder-Plassmann; Reinhard Pamler
Journal:  J Endovasc Ther       Date:  2002-06       Impact factor: 3.487