Literature DB >> 22475466

Passivity of fit of CAD/CAM and copy-milled frameworks, veneered frameworks, and anatomically contoured, zirconia ceramic, implant-supported fixed prostheses.

Matthias Karl1, Friedrich Graef, Manfred Wichmann, Tim Krafft.   

Abstract

STATEMENT OF PROBLEM: There is less information on the quality of fit of zirconia frameworks with or without ceramic veneer than on anatomically contoured milled zirconia restorations.
PURPOSE: The purpose of this in vitro study was to evaluate the strain development of CAD/CAM fabricated zirconia ceramic frameworks with and without ceramic veneering, copy-milled zirconia ceramic frameworks, and copy-milled zirconia ceramic anatomic contour restorations.
MATERIAL AND METHODS: Four groups of 3-unit implant-supported cement-retained restorations were fabricated (n=10) to fit an in vitro model with 2 implants. Strain gauges which recorded the strain development of all restorations during cementation were attached to the model mesially and distally adjacent to the implants. Mean absolute strain values were recorded for statistical analysis (MANOVA with Pillai's trace; α=.05).
RESULTS: Mean absolute strain development at the different strain gauge locations ranged from 83.23 µm/m for copy-milled zirconia ceramic anatomic contour restorations to 301.20 µm/m for veneered CAD/CAM fabricated zirconia ceramic restorations. Significant effects (P<.001) of the fixed factors restoration type and veneering status, as well as of their interaction term (P=.001) were found. Ceramic veneering of CAD/CAM frameworks resulted in higher strain development, whereas the greater volume in copy-milled anatomic contour restorations did not affect accuracy.
CONCLUSIONS: With the systems used in this study, zirconia ceramic-based anatomic contour restorations show greater passivity of fit than ceramic veneered CAD/CAM fabricated zirconia ceramic frameworks.
Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22475466     DOI: 10.1016/S0022-3913(12)60067-5

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  [Effect of materials and superstructure designs on the passive fit of implant-supported fixed prostheses].

Authors:  Shan Song; Zheng Zheng; Li-Yuan Yang; Xu Gao
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2019-02-01

2.  Esthetic Rehabilitation of Anterior Teeth with Copy-Milled Restorations: A Report of Two Cases.

Authors:  Sapna Rani; Jyoti Devi; Chandan Jain; Parul Mutneja; Mahesh Verma
Journal:  Case Rep Dent       Date:  2017-02-23

3.  Dimensional Changes of 3-Unit Implant-Supported Zirconia Frameworks of Two CAD/CAM Systems from Scanning to Sintering.

Authors:  Marzieh Alikhasi; Narges Ameri; Hakimeh Siadat; Ahmad Reza Shamshiri; Mohammadreza Nejati
Journal:  Front Dent       Date:  2019-06-29

4.  Anterosuperior rehabilitation with metal-free fixed prosthesis based on zirconia.

Authors:  Sthelen Nayara Cenci; Igor Alessandro Gontarsky; Marcella Goetz Moro; Lidia Olga Bach Pinheiro; Adriana Postiglione Bührer Samra
Journal:  Eur J Dent       Date:  2017 Apr-Jun

5.  Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques.

Authors:  Ying Zhou; Yong Li; Xiao Ma; Yiqing Huang; Jiawei Wang
Journal:  J Adv Prosthodont       Date:  2017-04-06       Impact factor: 1.904

6.  A strain gauge analysis comparing 4-unit veneered zirconium dioxide implant-borne fixed dental prosthesis on engaging and non-engaging abutments before and after torque application.

Authors:  Alyssa Epprecht; Marco Zeltner; Goran Benic; Mutlu Özcan
Journal:  Clin Exp Dent Res       Date:  2018-02-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.