Literature DB >> 22473068

The safe zone for external fixator pins in the femur.

Michael J Beltran1, Cory A Collinge, Jeanne C Patzkowski, Brendan D Masini, Robert E Blease, Joseph R Hsu.   

Abstract

OBJECTIVE: To define the anatomic "safe zone" for placement of external fixator half pins into the anterior and lateral femur.
METHODS: In 20 fresh-frozen hemipelvis specimens, the femoral nerve and all branches crossing the femur were dissected out to their final muscular locations. The location where the nerves crossed the anterior femur was measured from the anterior superior iliac spine and inferior margin of the lesser trochanter. The knee joint was then opened, and the distance from the superior reflection of the suprapatellar pouch to the last branch of the femoral nerve crossing the anterior femur was measured, defining the safe zone for anterior pin placement.
RESULTS: The last branch of the femoral nerve crossed at an average distance from the anterior superior iliac spine of 174 ± 43 mm (range, 95-248 mm) and from the lesser trochanter at a distance of 58 ± 36 mm (range, 0-136 mm). The average distance from the proximal pole of the patella to the superior reflection of the suprapatellar pouch was 46.3 ± 13.1 mm (range, 20-74 mm). Using the linear distance between the last crossing femoral nerve branch and the superior reflection of the pouch, the average safe zone measured 199 ± 39.8 mm (range, 124-268 mm). The safe zone correlated with thigh length (r = 0.48, P = 0.03). All nerve branches terminated at their muscular origins without crossing lateral to a line from the anterior greater trochanter to the anterior aspect of the lateral femoral condyle.
CONCLUSIONS: The safe zone for anterior external fixator half pin placement into the femur is on average 20 cm in length and can be as narrow as 12 cm. Anterior pins should begin 7.5 cm above the superior pole of the patella to avoid inadvertent knee joint penetration. Because the entire lateral femur is safely available for half pin placement, including distally, we recommend the use of alternative frame constructs with either anterolateral or lateral pins given the limitations and risks of anterior pin placement.

Entities:  

Mesh:

Year:  2012        PMID: 22473068     DOI: 10.1097/BOT.0b013e31824aed95

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  3 in total

1.  Vascular Complications during Ilizarov Fixator Surgery to the Femur: Two Case Reports with the Introduction of a Method for Determining the Safe Vascular Corridor around the Femur.

Authors:  Ashraf A Khanfour; Ayman A Khanfour
Journal:  Strategies Trauma Limb Reconstr       Date:  2019 May-Aug

2.  Periarticular Fractures of the Knee in Polytrauma Patients.

Authors:  M L Bertrand; P Andrés-Cano; F J Pascual-López
Journal:  Open Orthop J       Date:  2015-07-31

3.  Surgical Approaches to the Proximal Humerus: A Quantitative Comparison of the Deltopectoral Approach and the Anterolateral Acromial Approach.

Authors:  Luke S Harmer; Colin V Crickard; Kevin D Phelps; R Randall McKnight; Katherine M Sample; Erica B Andrews; Nady Hamid; Joseph R Hsu
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2018-06-13
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.