Literature DB >> 22469026

Three-years clinical outcome of immediate provisionalization of single Osseospeed(™) implants in extraction sockets and healed ridges.

Hugo De Bruyn1, Filiep Raes, Lyndon F Cooper, Glenn Reside, Joan S Garriga, Luís G Tarrida, Jörg Wiltfang, Matthias Kern.   

Abstract

AIM: The purpose of this prospective multicenter clinical study was to compare 3 years implant survival, bone and soft tissue changes following immediate loading using single Osseospeed(™) implants (Astra Tech AB, Mölndal, Sweden) installed in healed ridges or extraction sockets.
MATERIAL AND METHODS: Implants were provisionally restored the day of surgery using cemented acrylic crowns out of full occlusion. The provisional crowns were replaced after 12 weeks by full-ceramic crowns. Implant survival, bone levels, soft tissue levels and peri-implant health were monitored up to 3 years.
RESULTS: 55 patients (22 men, 33 women; mean age 45) had the implant installed in extraction sockets and 58 patients (25 men, 33 women; mean age 42) received conventional implant treatment in healed ridges. Three implants failed in the extraction group and one implant failed in the healed group, all failures occurred before the final crown placement. No further losses occurred during 3 years, giving a statistically comparable survival rate of 94.6% and 98.3%, respectively. The total bone loss after 3 years, compared to implant placement was 0.4 mm (SD 1.5) in healed sites, whilst the immediate sites showed a bone gain of 1.6 mm (SD 2.4) due to bone fill in the alveolus. Papillae retracted with 0.3 and 0.0 mm in the period of provisionalization, but grew back after final crown was placed with 0.3 and 0.5 mm in extraction and healed sites respectively after 3 years. Plaque and inflammation scores were very low throughout the study time, irrespective of treatment modality.
CONCLUSIONS: Immediate implants restored at the day of surgery show comparable risk for implant failure, bone loss and midfacial soft tissue recession compared to conventionally installed implants. The 3-years results suggest both hard and soft tissue stability.
© 2012 John Wiley & Sons A/S.

Entities:  

Mesh:

Year:  2012        PMID: 22469026     DOI: 10.1111/j.1600-0501.2012.02449.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  10 in total

1.  Radiological evaluation of the Cresco system in combination with Osseospeed implants: a preliminary 3-year report.

Authors:  N Baldini; M DE Sanctis; M C Cagidiaco; P Balleri; F Vignoletti; C Goracci; M Ferrari
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

2.  Success and patient satisfaction of immediately loaded zirconia implants with fixed restorations one year after loading.

Authors:  Rico Rutkowski; Ralf Smeets; Leon Neuhöffer; Carolin Stolzer; Kilian Strick; Martin Gosau; Susanne Sehner; Karl Ulrich Volz; Anders Henningsen
Journal:  BMC Oral Health       Date:  2022-05-23       Impact factor: 3.747

3.  Immediate Placement and Restoration of a New Tapered Implant System in the Aesthetic Region: A Report of Three Cases.

Authors:  Caroliene M Meijndert; Gerry M Raghoebar; Arjan Vissink; Henny J A Meijer
Journal:  Case Rep Dent       Date:  2020-07-25

4.  Reality of dental implant surface modification: a short literature review.

Authors:  In-Sung Yeo
Journal:  Open Biomed Eng J       Date:  2014-10-31

5.  Comparative evaluation of the stability of two different dental implant designs and surgical protocols-a pilot study.

Authors:  David E Simmons; Pooja Maney; Austin G Teitelbaum; Susan Billiot; Lomesh J Popat; A Archontia Palaiologou
Journal:  Int J Implant Dent       Date:  2017-05-02

6.  The effects of hard and soft tissue grafting and individualization of healing abutments at immediate implants: an experimental study in dogs.

Authors:  Daniel S Thoma; Ui-Won Jung; Alfonso Gil; Myong Ji Kim; Kyeong-Won Paeng; Ronald E Jung; Stefan Fickl
Journal:  J Periodontal Implant Sci       Date:  2019-06-07       Impact factor: 2.614

Review 7.  A Systematic Review of Survival Rates of Osseointegrated Implants in Fully and Partially Edentulous Patients Following Immediate Loading.

Authors:  Massimo Del Fabbro; Tiziano Testori; Vladan Kekovic; Funda Goker; Margherita Tumedei; Hom-Lay Wang
Journal:  J Clin Med       Date:  2019-12-04       Impact factor: 4.241

8.  Bone Morphometric Evaluation around Immediately Placed Implants Covered with Porcine-Derived Pericardium Membrane: An Experimental Study in Dogs.

Authors:  Ryo Jimbo; Charles Marin; Lukasz Witek; Marcelo Suzuki; Nick Tovar; Ioana Chesnoiu-Matei; Irina Florentina Dragan; Paulo G Coelho
Journal:  Int J Biomater       Date:  2012-11-25

9.  A 5-year comparison of marginal bone level following immediate loading of single-tooth implants placed in healed alveolar ridges and extraction sockets in the maxilla.

Authors:  Antoine N Berberi; Joseph M Sabbagh; Moustafa N Aboushelib; Ziad F Noujeim; Ziad A Salameh
Journal:  Front Physiol       Date:  2014-01-31       Impact factor: 4.566

Review 10.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.