Literature DB >> 22468356

Determination of total iodine in infant formula and nutritional products by inductively coupled plasma/mass spectrometry: single-laboratory validation.

Lawrence H Pacquette1, Alan M Levenson, Joseph J Thompson.   

Abstract

A single-laboratory validation by inductively coupled plasma-mass spectrometry was developed for the determination total iodine (m/z 127) in infant formula and adult nutritional products. All samples were digested in nitric acid using a closed vessel microwave oven system; Te (m/z 130) was used as an internal standard. To prevent loss of iodine, ammonium hydroxide solution was added to the samples immediately after digestion. The method quantitation limit for total iodine was 0.3 ng/mL, but a practical LOQ was used at 1.0 ng/mL, a concentration at which there was a negligible bias due to nonlinearity. The total iodine concentrations (112-1900 ng/g) in 14 out of 15 nutritional products were within specification limits. Within-day and day-to-day (6 independent days) precision values were < 10% RSD. The observed precision for the overall mean (18 independent days) of a control sample was approximately 4% RSD. In two National Institute of Standards and Technology standard reference materials, total iodine results were within certified limits. Sample spike recoveries for all 15 nutritional products were 92-105%. The data show that a conventional microwave oven digestion procedure can be used to prepare samples for iodine determination. Therefore, this technique is very compatible with other methods being proposed as modern official methods for the analysis of minerals in nutritional products.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22468356     DOI: 10.5740/jaoacint.10-472

Source DB:  PubMed          Journal:  J AOAC Int        ISSN: 1060-3271            Impact factor:   1.913


  3 in total

1.  Analysis of iodine in food samples by inductively coupled plasma-mass spectrometry.

Authors:  Todor I Todorov; Patrick J Gray
Journal:  Food Addit Contam Part A Chem Anal Control Expo Risk Assess       Date:  2016-01-11

2.  Optimization of a New Mass Spectrometry Method for Measurement of Breast Milk Iodine Concentrations and an Assessment of the Effect of Analytic Method and Timing of Within-Feed Sample Collection on Breast Milk Iodine Concentrations.

Authors:  Susanne Dold; Jeannine Baumgartner; Christophe Zeder; Adam Krzystek; Jennifer Osei; Max Haldimann; Michael B Zimmermann; Maria Andersson
Journal:  Thyroid       Date:  2015-12-18       Impact factor: 6.568

Review 3.  The Role of Iodine for Thyroid Function in Lactating Women and Infants.

Authors:  Maria Andersson; Christian P Braegger
Journal:  Endocr Rev       Date:  2022-05-12       Impact factor: 25.261

  3 in total