The role of vestibular caloric tests in cochlear implantation.

Amit Parmar1, Julian Savage, Andrew Wilkinson, Daniel Hajioff, Desmond A Nunez, Philip Robinson.   

Abstract

OBJECTIVE: Vestibular function tests are often undertaken before cochlear implantation, in part to help select the side of surgery. The authors aim to determine whether implantation on the side of better vestibular function leads to greater perception of dizziness by patients than implantation on the side of worse or similar function. STUDY
DESIGN: Historical cohort study.
SETTING: Tertiary cochlear implantation center. SUBJECTS AND METHODS: The records of 177 adult recipients of a unilateral cochlear implant were reviewed retrospectively in 2 groups. Group A included patients with an implant in the ear with worse or similar caloric responses. Group B included patients with an implant in the ear with the stronger caloric response. All patients underwent preoperative bithermal caloric testing: a clinically significant difference was defined by a 20% lateral canal paresis. They were assessed postoperatively by the Dizziness Handicap Inventory and supplementary questions.
RESULTS: Fifty-seven percent of both groups reported dizziness in the first 7 days postoperatively. At 2 months, 20% of group A and 34% of group B experienced some dizziness. Fourteen percent of group A and 10% of group B felt that cochlear implantation had resulted in impaired balance. The Dizziness Handicap Inventory scores of 86% of group A (median score 0) and 76% of group B (median score 10) corresponded with low handicap. None of these results differed significantly between groups A and B.
CONCLUSION: Although cochlear implantation may result in dizziness, it is almost always short-lived and mild, even when the ear with the stronger caloric response is implanted.

Entities:  

Mesh:

Year:  2012        PMID: 22467287     DOI: 10.1177/0194599812442059

Source DB:  PubMed          Journal:  Otolaryngol Head Neck Surg        ISSN: 0194-5998            Impact factor:   3.497


  2 in total

1.  Lateral Semicircular Canal Pressures During Cochlear Implant Electrode Insertion: a Possible Mechanism for Postoperative Vestibular Loss.

Authors:  Renee M Banakis Hartl; Nathaniel T Greene; Herman A Jenkins; Stephen P Cass; Daniel J Tollin
Journal:  Otol Neurotol       Date:  2018-07       Impact factor: 2.311

Review 2.  Surgery of the ear and the lateral skull base: pitfalls and complications.

Authors:  Bernhard Schick; Julia Dlugaiczyk
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2013-12-13
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.