Literature DB >> 22467048

Analysis of tantalum implants used for avascular necrosis of the femoral head: a review of five retrieved specimens.

Mariano Fernández-Fairen1, Antonio Murcia, Roberto Iglesias, Pablo Sevilla, José Maria Manero, Francisco Javier Gil.   

Abstract

AIM: The effective results shown in the porous systems of tantalum employed for the use of osseointegrates has been demonstrated by means of animal experimentation. However, there is a total lack of any research studies on the osseointegration of tantalum implants from retrieval of the same after a period of time whereby the material had been implanted within the human body.
MATERIALS AND METHODS: For this study, five rod implants used for the treatment of avascular necrosis of the femoral head were retrieved following collapse of the femoral head and conversion to total hip arthroplasty. The time of implantation ranged between six weeks and twenty months.
RESULTS: Observation during this study has confirmed the effectiveness of osseointegration within this period of time. New bone was observed around and within the porous system of the on rod devices at retrieval date. The bone ingrowth, however, proved to be slower and less intense than that resulting within animal species during the first few months after implantation.
CONCLUSIONS: Nevertheless, the results obtained in the quantitative assessment of this process proved to be similar to those results achieved by other authors in previous experimental work studies.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22467048     DOI: 10.5301/JABFM.2012.9273

Source DB:  PubMed          Journal:  J Appl Biomater Funct Mater        ISSN: 2280-8000            Impact factor:   2.604


  7 in total

1.  Bioactive macroporous titanium implants highly interconnected.

Authors:  Cristina Caparrós; Mónica Ortiz-Hernandez; Meritxell Molmeneu; Miguel Punset; José Antonio Calero; Conrado Aparicio; Mariano Fernández-Fairén; Román Perez; Francisco Javier Gil
Journal:  J Mater Sci Mater Med       Date:  2016-08-31       Impact factor: 3.896

2.  Real-time computerised tomography assisted porous tantalum implant in ARCO stage I-II non-traumatic osteonecrosis of the femoral head: minimum five-year follow up.

Authors:  Ruyin Hu; Pengfei Lei; Bo Li; Hao Liu; Xucheng Yang; Ting Wen; Yihe Hu; Xiaobin Tian
Journal:  Int Orthop       Date:  2018-03-27       Impact factor: 3.075

3.  Histological ex vivo analysis of retrieved human tantalum augmentations.

Authors:  Stefan Breer; Michael Hahn; Daniel Kendoff; Matthias Krause; Till Koehne; Carl Haasper; Thorsten Gehrke; Michael Amling; Matthias Gebauer
Journal:  Int Orthop       Date:  2012-08-15       Impact factor: 3.075

4.  Bone ingrowth in well-fixed retrieved porous tantalum implants.

Authors:  Josa A Hanzlik; Judd S Day
Journal:  J Arthroplasty       Date:  2013-03-18       Impact factor: 4.757

5.  Total hip arthroplasty following failure of tantalum rod implantation for osteonecrosis of the femoral head with 5- to 10-year follow-up.

Authors:  Qi Cheng; Jin-Long Tang; Jiang-Jiang Gu; Kai-Jin Guo; Wang-Shou Guo; Bai-Liang Wang; Feng-Chao Zhao
Journal:  BMC Musculoskelet Disord       Date:  2018-08-16       Impact factor: 2.362

6.  The Comparative Analysis of Antegrade Versus Retrograde Approach for a Failed Porous Tantalum Rod Removal During Conversion to Total Hip Arthroplasty.

Authors:  Fengchao Zhao; Li Zheng; Qi Cheng; Weifan Hu; Bailiang Wang
Journal:  Med Sci Monit       Date:  2020-05-14

7.  Two Different Strategies to Enhance Osseointegration in Porous Titanium: Inorganic Thermo-Chemical Treatment Versus Organic Coating by Peptide Adsorption.

Authors:  Monica Ortiz-Hernandez; Katrin S Rappe; Meritxell Molmeneu; Carles Mas-Moruno; Jordi Guillem-Marti; Miquel Punset; Cristina Caparros; Jose Calero; Jordi Franch; Mariano Fernandez-Fairen; Javier Gil
Journal:  Int J Mol Sci       Date:  2018-08-30       Impact factor: 5.923

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.