Literature DB >> 22464523

Real-time cell analysis of the cytotoxicity of orthodontic mini-implants on human gingival fibroblasts and mouse osteoblasts.

Siddik Malkoç1, Firat Öztürk, Bayram Çörekçi, Buket S Bozkurt, Sema S Hakki.   

Abstract

INTRODUCTION: The aim of this study was to evaluate the cytotoxic effects of orthodontic mini-implants on gingival fibroblasts and osteoblasts.
METHODS: The orthodontic mini-implants used in this study were Orthodontic Mini Implant (Leone, Florence, Italy), MTN (MTN, Istanbul, Turkey), AbsoAnchor (Dentos, Daegu, South Korea), IMTEC Ortho (3M Unitek, IMTEC, Ardmore, Okla), VectorTAS (Ormco, Glendora, Calif). The materials were incubated in Dulbecco's modified eagle's culture medium for 72 hours according to ISO 10993-5 standards (surface area-to-volume ratio of the specimen to cell-culture medium, 3 cm(2)/mL). A real-time cell analyzer (xCELLigence, Roche Applied Science, Mannheim, Germany; ACEA Biosciences, San Diego, Calif) was used to evaluate cell survival. After seeding 200 μL of the cell suspensions into the wells of the E-plate 96, gingival fibroblasts were treated with bioactive components released by the metallic materials and monitored every 15 minutes for 190 hours. For the proliferation experiments, the statistical analyses used were 1-way analysis of variance and Tukey-Kramer multiple comparisons tests.
RESULTS: There was no significant differences between the human gingival fibroblast cell indexes of the control and study groups (P >0.05). When evaluated at 27 and 96 hours, only the VectorTAS mini-implants showed statistically significant decreases in the M3T3 cell index (P <0.001) compared with the control group. No significant differences were found among the control and all study groups (P >0.05). Furthermore, the Leone and MTN mini-implants showed statistically significant decreases (P <0.001) at 190 hours. Also, the VectorTAS mini-implants demonstrated a significant decline (P <0.05) at the same time in the M3T3 cell index.
CONCLUSIONS: These findings provide fundamental knowledge and new insights for future design and development of new biocompatible titanium alloys for orthodontic mini-implants and temporary anchorage devices.
Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22464523     DOI: 10.1016/j.ajodo.2011.12.009

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  9 in total

1.  Miniscrews for orthodontic anchorage: nanoscale chemical surface analyses.

Authors:  Justin Silverstein; Osmar Barreto; Rodrigo França
Journal:  Eur J Orthod       Date:  2015-03-13       Impact factor: 3.075

2.  Cellular attachment and differentiation on titania nanotubes exposed to air- or nitrogen-based non-thermal atmospheric pressure plasma.

Authors:  Hye Yeon Seo; Jae-Sung Kwon; Yu-Ri Choi; Kwang-Mahn Kim; Eun Ha Choi; Kyoung-Nam Kim
Journal:  PLoS One       Date:  2014-11-24       Impact factor: 3.240

3.  Cytotoxicity of temporary cements on bovine dental pulp-derived cells (bDPCs) using realtime cell analysis.

Authors:  Meral Arslan Malkoç; Necla Demİr; Abdulkadir Şengün; Şerife Buket Bozkurt; Sema Sezgin Hakki
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

4.  Cell Type-Specific Adhesion and Migration on Laser-Structured Opaque Surfaces.

Authors:  Jörn Schaeske; Elena Fadeeva; Sabrina Schlie-Wolter; Andrea Deiwick; Boris N Chichkov; Alexandra Ingendoh-Tsakmakidis; Meike Stiesch; Andreas Winkel
Journal:  Int J Mol Sci       Date:  2020-11-10       Impact factor: 5.923

5.  Comparative Toxicological In Vitro and In Ovo Screening of Different Orthodontic Implants Currently Used in Dentistry.

Authors:  Camelia A Szuhanek; Claudia G Watz; Ștefana Avram; Elena-Alina Moacă; Ciprian V Mihali; Adelina Popa; Andrada A Campan; Mirela Nicolov; Cristina A Dehelean
Journal:  Materials (Basel)       Date:  2020-12-13       Impact factor: 3.623

6.  Cytotoxicity effect of orthodontic miniscrew-implant in different types of mouthwash: An in-vitro study.

Authors:  Wulan S Utami; Haru S Anggani; Maria Purbiati
Journal:  J Orthod Sci       Date:  2022-01-28

7.  In vitro study of the orthodontic mini-implants influence on the growth of human osteoblasts.

Authors:  Andreea Moldoveanu; Mihnea Ioan Nicolescu; Mirela Veronica Bucur; George Gabriel Moldoveanu; Cristian Funieru; Ionela Victoria Neagoe; Gina Manda; Tamara Rahela Ioana; Lucian Toma Ciocan
Journal:  Rom J Morphol Embryol       Date:  2021 Jul-Sep       Impact factor: 0.833

8.  Cytotoxicity of orthodontic temporary anchorage devices on human periodontal ligament fibroblasts in vitro.

Authors:  Zhibin Chen; Manika Patwari; Dawei Liu
Journal:  Clin Exp Dent Res       Date:  2019-08-08

Review 9.  Is titanium alloy Ti-6Al-4 V cytotoxic to gingival fibroblasts-A systematic review.

Authors:  Jonathan Willis; Siwei Li; St John Crean; Fadi N Barrak
Journal:  Clin Exp Dent Res       Date:  2021-05-21
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.