Literature DB >> 2246300

Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties.

P P Anthony1, G A Gie, C R Howie, R S Ling.   

Abstract

Four cases are described of localised endosteal bone lysis in the femur occurring in association with cemented femoral components that were not obviously 'loose' radiologically. In each, the area of lysis was shown at operation to be related directly to a region in which there was a local defect in the cement mantle surrounding the stem. Via the space between the stem and cement, such defects provide a route through which the contents of the joint cavity may reach the endosteal surface of the femur, subsequently leading to localised bone lysis, and later to frank loosening.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2246300

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  36 in total

1.  The femoral cement mantle in three total hip replacements.

Authors:  S J Mellor; L G Ripley; D M Ricketts
Journal:  Int Orthop       Date:  2003-10-08       Impact factor: 3.075

2.  Coordinating retrieval and register studies improves postmarket surveillance.

Authors:  Peter Ellison; Geir Hallan; Paul Johan Høl; Nils Roar Gjerdet; Leif I Havelin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

Review 3.  The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses.

Authors:  Peter A Revell
Journal:  J R Soc Interface       Date:  2008-11-06       Impact factor: 4.118

4.  Using 'subcement' to simulate the long-term fatigue response of cemented femoral stems in a cadaver model: could a novel preclinical screening test have caught the Exeter matt problem?

Authors:  A Race; M A Miller; K A Mann
Journal:  Proc Inst Mech Eng H       Date:  2010       Impact factor: 1.617

5.  The Elite-Plus stem migrates more than the flanged Charnley stem.

Authors:  Thord von Schewelov; Lennart Sanzén; Jack Besjakov; Ake Carlsson
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

6.  Basic science considerations in primary total hip replacement arthroplasty.

Authors:  Saqeb B Mirza; Douglas G Dunlop; Sukhmeet S Panesar; Syed G Naqvi; Shafat Gangoo; Saif Salih
Journal:  Open Orthop J       Date:  2010-05-11

7.  The posterior approach reduces the risk of thin cement mantles with a straight femoral stem design.

Authors:  Gavin J Macpherson; Christian Hank; Michael Schneider; Morag Trayner; Robert Elton; Colin R Howie; Steffen J Breusch
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

8.  In vitro comparison of the effects of rough and polished stem surface finish on pressure generation in cemented hip arthroplasty.

Authors:  Gavin E Bartlett; David J Beard; David W Murray; Harinderjit S Gill
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

9.  18 years of results with cemented primary hip prostheses in the Norwegian Arthroplasty Register: concerns about some newer implants.

Authors:  Birgitte Espehaug; Ove Furnes; Lars B Engesaeter; Leif I Havelin
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

10.  In vitro influence of stem surface finish and mantle conformity on pressure generation in cemented hip arthroplasty.

Authors:  Gavin E Bartlett; Harinderjit S Gill; David W Murray; David J Beard
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.