The "puffed cheek method" to evaluate mucosal thickness: case series.

G Dvorak1, C Arnhart, P Schön, S Heuberer, G Watzek, A Gahleitner.   

Abstract

OBJECTIVES: Mucosal thickness should be considered in implant treatment planning. Needle probing to measure mucosal thickness is invasive and therefore not used in routine diagnosis. The "puffed cheek" method is an established technique to visualize the vestibule in computed tomography (CT). As CT assesses bone availability, a simultaneous mucosal thickness measurement would be useful. The aim of this study was to evaluate the reliability of mucosal thickness measurement in CT with distended cheeks.
MATERIALS AND METHODS: Buccal maxillary mucosa thickness was evaluated at four measurement sites in the incisor and molar area of 11 patients. Each site was evaluated via CT with cheek distension and needle probing. Measurement area was identified with the aid of a thermoplastic splint to localize the exact position by a gutta-percha marker point. The comparison between the two methods was performed by Bland-Altman diagram.
RESULTS: The mean clinical thickness was 1.17 mm (±0.31) compared to 1.11 mm (±0.31) in CT evaluation. The mean difference between the two methods was 0.07 mm (±0.40; CI-0.14;0.12, P = 0.88, Krippendorff α = 0.38). According to Bland-Altman diagram the mucosal thickness may diverge by up to 0.9 mm from the radiologic thickness.
CONCLUSIONS: The two measurement methods may not be interchangeably used. As additional information to three-dimensional bone analyses, CT may be performed as a pre-operative soft tissue analysis at most implant sites with distended cheeks. Nevertheless, this method yields less valid and reliable results than the gold standard.
© 2012 John Wiley & Sons A/S.

Entities:  

Mesh:

Year:  2012        PMID: 22462565     DOI: 10.1111/j.1600-0501.2012.02469.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  2 in total

Review 1.  Biomechanics of oral mucosa.

Authors:  Junning Chen; Rohana Ahmad; Wei Li; Michael Swain; Qing Li
Journal:  J R Soc Interface       Date:  2015-08-06       Impact factor: 4.118

2.  Comparative in vitro study of two methods for gingival biotype assessment.

Authors:  Leticia Sala; Raquel Alonso-Pérez; Ruben Agustin-Panadero; Alberto Ferreiroa; Ana Carrillo-de-Albornoz
Journal:  J Clin Exp Dent       Date:  2018-09-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.