Literature DB >> 22460775

Radiation exposure from diagnostic imaging in the pediatric intensive care unit.

Heather Strawbridge1, Geoffrey Kurland, R Scott Watson, Michael Sheetz, Stefanie Wilkinson, Daniel J Weiner.   

Abstract

OBJECTIVE: To determine the range of radiation exposure from diagnostic imaging in children requiring mechanical ventilation.
DESIGN: Prospective, observational.
SETTING: Tertiary pediatric critical care unit. PATIENTS: We enrolled pediatric critical care unit patients requiring mechanical ventilation.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Thoracic radiation exposure while the patient was in the pediatric critical care unit was measured using a small, radiolucent dosimeter secured to the anterior chest wall. Demographic data, diagnoses, and number and type of radiographic procedures were recorded. Differences between exposures by admission diagnoses were analyzed by rank sum test. Relationships between exposure and risk factors were assessed using multiple linear regression and Pearson correlation. Sixty-nine subjects were enrolled over a 175-day period. Subjects experienced a mean (± SD) of 11 ± 11 days of mechanical ventilation during which they underwent a mean of 14 ± 16 chest radiographs and 5 ± 4 other plain films. Subjects who had only plain radiographic studies (CXR group) had a median thoracic exposure of 1.02 (range, 0.13-28.26) mGy and a median daily exposure of 0.16 (range, 0.02-1.99) mGy/day. Subjects who had computed tomography and/or fluoroscopy studies in addition to plain radiographs (CXR+ group) had a median total thoracic exposure of 3.71 (range, 0.77-33.41) mGy and median daily exposure of 0.37 (range, 0.04-3.71) mGy/day, both of which were significantly higher than for subjects in the CXR group. There was no significant difference in average daily exposures according to admission diagnoses and daily exposure could not be predicted from a combination of variables, including age, body mass index, gender, or length of stay. Total number of radiologic studies was correlated, as expected, with duration of ventilation (r = 0.941, p < .0001). Exposure was significantly higher in patients who underwent computed tomography scans or fluoroscopy studies than in patients who only had plain radiography.
CONCLUSIONS: Ventilated pediatric intensive care unit patients experienced an average daily thoracic radiation exposure above background environmental exposure and exposure varied widely, but exposures would not be expected to cause acute or chronic toxicity. Overall patient exposures were less than that received from 1 yr of natural background radiation.

Entities:  

Mesh:

Year:  2012        PMID: 22460775     DOI: 10.1097/PCC.0b013e31823c9a26

Source DB:  PubMed          Journal:  Pediatr Crit Care Med        ISSN: 1529-7535            Impact factor:   3.624


  3 in total

1.  Unexpected Salter-Harris type II fracture of the proximal phalanx of the second toe: a chiropractic perspective.

Authors:  Mark Murdock
Journal:  J Can Chiropr Assoc       Date:  2015-12

2.  Cumulative radiation exposure from diagnostic imaging in intensive care unit patients.

Authors:  Fiachra Moloney; Daniel Fama; Maria Twomey; Ruth O'Leary; Conor Houlihane; Kevin P Murphy; Siobhan B O'Neill; Owen J O'Connor; Dorothy Breen; Michael M Maher
Journal:  World J Radiol       Date:  2016-04-28

3.  Radiation Exposure from Diagnostic Imaging in a Cohort of Pediatric Transplant Recipients.

Authors:  Alexandra Seal; Michael Hawkes; Ravi Bhargava; Michelle Noga; Jutta Preiksaitis; Curtis Mabilangan; Joan Robinson
Journal:  PLoS One       Date:  2017-01-12       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.