Literature DB >> 22460672

Comparison of surgical outcomes of large orbital fractures reconstructed with porous polyethylene channel and porous polyethylene titan barrier implants.

Chang Yeom Kim1, Byung Jin Jeong, Sang Yeul Lee, Jin Sook Yoon.   

Abstract

PURPOSE: To compare the postoperative outcomes of large orbital fractures repaired with porous polyethylene (PP) channel implants (PPCIs) and PP titan barrier implants (PPTBs).
METHODS: Medical records of 42 patients who underwent surgical reconstruction for a large orbital fracture with either PPCI or PPTB were reviewed retrospectively. The degree of diplopia, determined with a binocular single vision test, and enophthalmos, measured by a Hertel exophthalmometer, was compared between 2 implant groups. Orbital volumes were calculated using CT scans and the measuring tool.
RESULTS: Of the 42 patients examined, 16 received PPCI and 26 received PPTB. No significant difference in the degree of diplopia was observed between the 2 implant groups before surgery, and 1 and 3 months after surgery (p = 0.256, 0.408, and 0.432, respectively). Preoperative average enophthalmos measuring 1.28 mm and 1.04 mm was successfully corrected to 0.19 mm and 0.25 mm 3 months after reconstruction with PPCI and PPTB, respectively. The fractured orbit volumes and nonfractured contralateral orbit volumes were 24.96 ± 2.32 cm3 and 23.18 ± 1.733 cm in the PPCI group, and 26.80 ± 2.10 cm3 and 24.13 ± 2.28 cm3 in the PPTB group, respectively. After surgery, the fractured orbit volumes significantly decreased to 23.39 ± 2.82 cm3 in the PPCI group and to 23.53 ± 1.74 cm3 in the PPTB group; these values were not significantly different from that of the nonfractured orbit (p = 0.681 for PPCI and 0.204 for PPTB).
CONCLUSIONS: Porous polyethylene channel implant and PPTB are both effective implant materials for the repair of large orbital fractures; however, PPTB has the additional benefit of not requiring screw fixation.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22460672     DOI: 10.1097/IOP.0b013e3182467c4a

Source DB:  PubMed          Journal:  Ophthalmic Plast Reconstr Surg        ISSN: 0740-9303            Impact factor:   1.746


  4 in total

1.  The better surgical timing and approach for orbital fracture: a systematic review and meta-analysis.

Authors:  Jian Zhang; Xin He; Yanxiu Qi; Pingping Zhou
Journal:  Ann Transl Med       Date:  2022-05

2.  Combined orbital floor and medial wall fractures involving the inferomedial strut: repair technique and case series using preshaped porous polyethylene/titanium implants.

Authors:  Raymond I Cho; Brett W Davies
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-05-31

3.  Comparison of pre-bent titanium mesh versus polyethylene implants in patient specific orbital reconstructions.

Authors:  Marcin Kozakiewicz; Piotr Szymor
Journal:  Head Face Med       Date:  2013-10-29       Impact factor: 2.151

4.  Reconstruction of Medial Wall Blowout Fracture Defect with a Combination of Resorbable Meshed Plate and Cancellous Bone Allograft.

Authors:  Jongweon Shin; Song I Park; Yunsup Hwang; Ho Kwon; Hyung-Sup Shim
Journal:  Biomed Res Int       Date:  2019-10-15       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.