Endothelial dysfunction following drug-eluting stent implantation: a systematic review of the literature.

Yoshiyasu Minami1, Hideaki Kaneda, Masahiro Inoue, Masayasu Ikutomi, Toshihiro Morita, Toshiaki Nakajima.   

Abstract

BACKGROUND: While several studies have reported endothelial dysfunction after drug-eluting stent (DES) implantation, their study methods differed and the results were varied. METHODS AND
RESULTS: A literature search was performed using PubMed where 14 clinical studies (537 patients) including two randomized trials were identified. All studies assessed endothelial dysfunction 3-14 months after stent implantation. In the acetylcholine (ACh) loading studies, significant vasoconstrictions were observed in proximal and distal segments after implantation of sirolimus-eluting (SES) and paclitaxel-eluting stents (PES) and a milder diameter change was observed after zotarolimus-eluting stent (ZES) implantation. Coronary diameter changes were greater in distal segments. Significant diameter change was not detected after bare metal stent (BMS) implantation. In the exercise examinations, vasoconstriction was observed in distal and proximal segments following SES and PES implantation, whereas vasodilation was observed in BMS. In the pacing examinations, vasoconstriction was observed in both SES and PES implantations in distal and proximal segments, whereas vasodilation was observed in not only BMS but ZES and biolimus-eluting stents (BES) as well.
CONCLUSION: In the chronic phase following stent implantation, marked abnormal vasoconstriction distally in the stent was observed in SES and PES implantation but not in ZES or BES, compared with BMS. To clarify the clinical implications and possible mechanisms of these findings, longer-term evaluation with larger patients is needed.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22459395     DOI: 10.1016/j.ijcard.2012.03.084

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  9 in total

1.  Enhanced drug delivery capabilities from stents coated with absorbable polymer and crystalline drug.

Authors:  Wenda C Carlyle; James B McClain; Abraham R Tzafriri; Lynn Bailey; Brett G Zani; Peter M Markham; James R L Stanley; Elazer R Edelman
Journal:  J Control Release       Date:  2012-07-16       Impact factor: 9.776

2.  Impact of drug-eluting stent-associated coronary artery spasm on 3-year clinical outcomes: A propensity score matching analysis.

Authors:  Jabar Ali; Seung-Woon Rha; Byoung Geol Choi; Jae Kyeong Byun; Se Yeon Choi; Jin Ah Cha; Soohyung Park; Kyuho Lee; Seungmin Back; Jieun Lee; Dong Oh Kang; Jah Yeon Choi; Seung-Young Roh; Jin Oh Na; Cheol Ung Choi; Jin-Won Kim; Eung Ju Kim; Chang Gyu Park; Hong Seog Seo; Mohammad Wasim; Zair Hassan
Journal:  Indian Heart J       Date:  2022-05-13

3.  Severe Coronary Artery Vasospasm after Mitral Valve Replacement in a Diabetic Patient with Previous Stent Implantation: A Case Report.

Authors:  Alexandra Iulia Stoica; Marius Harpa; Cosmin Marian Banceu; Judith Kovacs; Horatiu Suciu
Journal:  J Crit Care Med (Targu Mures)       Date:  2022-05-12

4.  Adenosine-induced coronary vasospasm following drug-eluting stent implantation.

Authors:  Naoya Matsumoto; Ken Nagao; Atsushi Hirayama; Shu Kasama
Journal:  BMJ Case Rep       Date:  2014-02-11

5.  Polymeric stent materials dysregulate macrophage and endothelial cell functions: implications for coronary artery stent.

Authors:  Xintong Wang; Angela L Zachman; Young Wook Chun; Fang-Wen Shen; Yu-Shik Hwang; Hak-Joon Sung
Journal:  Int J Cardiol       Date:  2014-04-25       Impact factor: 4.164

6.  Nine-month angiographic and two-year clinical follow-up of novel biodegradable-polymer arsenic trioxide-eluting stent versus durable-polymer sirolimus-eluting stent for coronary artery disease.

Authors:  Li Shen; Wei Yang; Jia-Sheng Yin; Xue-Bo Liu; Yi-Zhe Wu; Ai-Jun Sun; Ju-Ying Qian; Jun-Bo Ge
Journal:  Chin Med J (Engl)       Date:  2015-03-20       Impact factor: 2.628

7.  Similarities and differences in coatings for magnesium-based stents and orthopaedic implants.

Authors:  Jun Ma; Marc Thompson; Nan Zhao; Donghui Zhu
Journal:  J Orthop Translat       Date:  2014-04-05       Impact factor: 5.191

8.  Beta blockers versus calcium channel blockers for provocation of vasospastic angina after drug-eluting stent implantation: a multicentre prospective randomised trial.

Authors:  Mitsuaki Sawano; Toshiomi Katsuki; Shun Kohsaka; Takeshi Kitai; Koichi Tamita; Kotaro Obunai; Yukinori Ikegami; Takafumi Yamane; Ikuko Ueda; Ayaka Endo; Yuichiro Maekawa; Akio Kawamura; Keiichi Fukuda
Journal:  Open Heart       Date:  2020-10

9.  Comparison of Endothelial Dysfunction in Coronary Arteries with Bare Metal and 2nd-Generation Drug-Eluting Stents.

Authors:  Yusuke Akiyama; Tetsuya Matoba; Shunsuke Katsuki; Susumu Takase; Soichi Nakashiro; Yasuhiro Nakano; Kensuke Noma; Hiroyuki Tsutsui
Journal:  J Atheroscler Thromb       Date:  2021-02-19       Impact factor: 4.928

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.