Exogenous fluorescent tracer agents based on pegylated pyrazine dyes for real-time point-of-care measurement of glomerular filtration rate.

Amruta R Poreddy1, William L Neumann, John N Freskos, Raghavan Rajagopalan, Bethel Asmelash, Kimberly R Gaston, Richard M Fitch, Karen P Galen, Jeng-Jong Shieh, Richard B Dorshow.   

Abstract

Novel pyrazine carboxamides bearing hydrophilic poly(ethylene glycol) (PEG) moieties were designed, synthesized, and evaluated for use as fluorescent glomerular filtration rate (GFR) tracer agents. Among these, compounds 4d and 5c that contain about 48 ethylene oxide units in the PEG chain exhibited the most favorable physicochemical and renal clearance properties. In vitro studies show that these two compounds have low plasma protein binding, a necessary condition for renal excretion. In vivo animal model results show that 4d and 5c have a higher urine recovery of the injected dose than iothalamate (a commonly considered gold standard GFR agent). Pharmacokinetic studies show that these two compounds exhibit a plasma clearance equivalent to iothalamate, but with a faster (i.e. lower) terminal half-life than iothalamate (possibly from restricted distribution into the extracellular space due to large molecular size and hydrodynamic volume). Furthermore, the plasma clearance of 4d and 5c remained unchanged upon blockage of the tubular secretion pathway with probenecid, a necessary condition for establishment of clearance via glomerular filtration exclusively. Finally, noninvasive real-time monitoring of this class of compounds was demonstrated by pharmacokinetic clearance of 5c by optical measurements in rat model, which correlates strongly with plasma concentration of the tracer. Hence, 4d and 5c are promising candidates for translation to the clinic as exogenous fluorescent tracer agents in real-time point-of-care monitoring of GFR.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22459210     DOI: 10.1016/j.bmc.2012.03.015

Source DB:  PubMed          Journal:  Bioorg Med Chem        ISSN: 0968-0896            Impact factor:   3.641


  10 in total

Review 1.  GFR Estimating Equations and Liver Disease.

Authors:  Tomasz Beben; Dena E Rifkin
Journal:  Adv Chronic Kidney Dis       Date:  2015-09       Impact factor: 3.620

Review 2.  Quantifying Glomerular Filtration Rates in Acute Kidney Injury: A Requirement for Translational Success.

Authors:  Bruce A Molitoris; Erinn S Reilly
Journal:  Semin Nephrol       Date:  2016-01       Impact factor: 5.299

Review 3.  Rethinking CKD Evaluation: Should We Be Quantifying Basal or Stimulated GFR to Maximize Precision and Sensitivity?

Authors:  Bruce A Molitoris
Journal:  Am J Kidney Dis       Date:  2017-02-20       Impact factor: 8.860

4.  Reliability of transcutaneous measurement of renal function in various strains of conscious mice.

Authors:  Daniel Schock-Kusch; Stefania Geraci; Esther Ermeling; Yury Shulhevich; Carsten Sticht; Juergen Hesser; Dzmitry Stsepankou; Sabine Neudecker; Johannes Pill; Roland Schmitt; Anette Melk
Journal:  PLoS One       Date:  2013-08-19       Impact factor: 3.240

5.  Measuring glomerular filtration rate in acute kidney injury: yes, but not yet.

Authors:  Bruce A Molitoris
Journal:  Crit Care       Date:  2012-09-24       Impact factor: 9.097

6.  Measuring glomerular filtration rate in the intensive care unit: no substitutes please.

Authors:  Bruce A Molitoris
Journal:  Crit Care       Date:  2013-09-04       Impact factor: 9.097

Review 7.  Estimating renal function in old people: an in-depth review.

Authors:  Maharajan Raman; Rachel J Middleton; Philip A Kalra; Darren Green
Journal:  Int Urol Nephrol       Date:  2017-09-15       Impact factor: 2.370

Review 8.  Light-Emitting Agents for Noninvasive Assessment of Kidney Function.

Authors:  Jiaguo Huang; Norbert Gretz
Journal:  ChemistryOpen       Date:  2017-07-20       Impact factor: 2.911

9.  Zwitterionic near infrared fluorescent agents for noninvasive real-time transcutaneous assessment of kidney function.

Authors:  Jiaguo Huang; Stefanie Weinfurter; Cristina Daniele; Rossana Perciaccante; Rodeghiero Federica; Leopoldo Della Ciana; Johannes Pill; Norbert Gretz
Journal:  Chem Sci       Date:  2017-01-11       Impact factor: 9.825

10.  Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla: initial results.

Authors:  Frank G Zöllner; Daniel Schock-Kusch; Sandra Bäcker; Sabine Neudecker; Norbert Gretz; Lothar R Schad
Journal:  PLoS One       Date:  2013-11-18       Impact factor: 3.240

  10 in total