Literature DB >> 22458835

Safety and effectiveness of 5-mm and 10-mm electrothermal bipolar vessel sealers (LigaSure) in laparoscopic resections for sigmoid colon and rectal cancers.

Cem Gezen1, Metin Kement, Yunus E Altuntas, Nihat Aksakal, Nuri Okkabaz, Osman Civil, Selahattin Vural, Mustafa Oncel.   

Abstract

BACKGROUND: LigaSure™ (Covidien, Mansfield, MA) has been used in cases undergoing laparoscopic colon and rectal resections. This study aims to analyze the efficacy and safety of the 5-mm and 10-mm devices. SUBJECTS AND METHODS: Patients who received a laparoscopic or hand-assisted laparoscopic operation for a tumor located in the sigmoid colon or rectum since 2006 were abstracted from a prospectively designed database, and findings were analyzed in two groups based on size of the device used during the procedure. The videotapes of the procedures were watched, and operation reports were read to obtain further information on specific intra- and postoperative complications. Demographics, tumor and operation-related information, and postoperative data were compared.
RESULTS: Among 215 (128 [59.5%] males; median age, 59.5±13.8 years) patients, data obtained from the 5-mm (n=32) and 10-mm (n=183) groups were identical regarding demographics and data related to tumor (localization and stage) and operation (number of harvested lymph nodes, conversion rates, operation time, intraoperative bleeding, transfusion requirement, reoperation rates, complications, 30-day mortality, and length of hospital stay). However, more patients underwent an anterior resection in the 10-mm group than in the 5-mm group (31.7% versus 15.6%, P<.05). Further analyses found device-related bleeding in 8 (3.7%) cases (2 [6.3%] versus 6 [3.3%] in the 5-mm versus 10-mm group, respectively, P>.05), requiring further attempts for hemorrhage control (n=6), conversion to open surgery (n=1), or relaparotomy (n=1).
CONCLUSIONS: The 5-mm and 10-mm LigaSure devices are similarly effective and safe during laparoscopic sigmoid colon and rectal resections. Severe bleeding from larger vessels may be observed, requiring conversion to open surgery or relaparotomy.

Entities:  

Mesh:

Year:  2012        PMID: 22458835     DOI: 10.1089/lap.2012.0083

Source DB:  PubMed          Journal:  J Laparoendosc Adv Surg Tech A        ISSN: 1092-6429            Impact factor:   1.878


  2 in total

1.  Serum 1,3-Beta-D-Glucan Values During and After Laparoscopic and Open Intestinal Surgery.

Authors:  Alexander Szyszkowitz; Christoph Zurl; Anna Herzeg; Anton Berger; Geza Gemes; Martin Mitteregger; Florian Prüller; Juergen Prattes; Ines Zollner-Schwetz; Thomas Valentin; Martin Hoenigl; Robert Krause
Journal:  Open Forum Infect Dis       Date:  2018-11-08       Impact factor: 3.835

2.  Use of energy device in general surgical operations: impact on peri-operative outcomes.

Authors:  Olalekan Olasehinde; Afolabi Owojuyigbe; Adekunle Adeyemo; Arinzechukwu Mosanya; Olurotimi Aaron; Funmilola Wuraola; Temitope Owoniya; Temilola Owojuyigbe; Olusegun Alatise; Adewale Adisa
Journal:  BMC Surg       Date:  2022-03-09       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.