Literature DB >> 22458635

Comparison of optic disc parameters using spectral domain cirrus high-definition optical coherence tomography and confocal scanning laser ophthalmoscopy in normal eyes.

Hemma Resch1, Gabor Deak, Ivania Pereira, Clemens Vass.   

Abstract

PURPOSE: To compare Cirrus HD - optical coherence tomography (HD-OCT) with confocal scanning laser ophthalmoscopy (HRT 3) for analysis of optic disc parameters in healthy eyes.
METHODS: In 126 subjects, cup volume (CV), vertical cup/disc ratio (CDR), neuroretinal rim area (NRA), cup area (CA) and optic disc area (ODA) were measured with the Cirrus HD-OCT and HRT 3. These optic disc parameters were chosen for statistical analysis because they can be analysed in both OCT and HRT 3 and they are widely used parameters for glaucoma assessment.
RESULTS: Mean values and significances of paired t-tests for OCT and HRT were for CV: 0.099 ± 0.11 versus 0.082 ± 0.10 (p < 0.001), CA: 0.42 ± 0.31 versus 0.39 ± 0.31 (p < 0.001), CDR: 0.36 ± 0.17 versus 0.27 ± 0.21 (p < 0.001). NRA and ODA were not significantly different between instruments. The Pearson coefficients were 0.905 (CV), 0.824 (CA), 0.734 (CDR), 0.295 (NRA) and 0.378 (ODA).
CONCLUSION: To our interpretation, the delineation of the optic disc border is error-prone with both instruments and all parameters directly depending on it are thus poorly correlated. However, the determination of the optic disc excavation (CV and CA) appears comparable taking into account a small systematic difference between instruments.
© 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

Entities:  

Mesh:

Year:  2012        PMID: 22458635     DOI: 10.1111/j.1755-3768.2012.02385.x

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  4 in total

Review 1.  The use of deep learning technology for the detection of optic neuropathy.

Authors:  Mei Li; Chao Wan
Journal:  Quant Imaging Med Surg       Date:  2022-03

2.  Enhanced detection of open-angle glaucoma with an anatomically accurate optical coherence tomography-derived neuroretinal rim parameter.

Authors:  Balwantray C Chauhan; Neil O'Leary; Faisal A AlMobarak; Alexandre S C Reis; Hongli Yang; Glen P Sharpe; Donna M Hutchison; Marcelo T Nicolela; Claude F Burgoyne
Journal:  Ophthalmology       Date:  2012-12-23       Impact factor: 12.079

3.  Optic nerve head parameters of high-definition optical coherence tomography and Heidelberg retina tomogram in perimetric and preperimetric glaucoma.

Authors:  Viquar Unnisa Begum; Uday Kumar Addepalli; Sirisha Senthil; Chandra Sekhar Garudadri; Harsha Laxmana Rao
Journal:  Indian J Ophthalmol       Date:  2016-04       Impact factor: 1.848

4.  The impact of optic nerve and related characteristics on disc area measurements derived from different imaging techniques.

Authors:  Michael Yapp; George Rennie; Michael P Hennessy; Michael Kalloniatis; Barbara Zangerl
Journal:  PLoS One       Date:  2018-01-17       Impact factor: 3.240

  4 in total