Literature DB >> 2245536

The biomechanical problems of polyethylene as a bearing surface.

J P Collier1, M B Mayor, V A Surprenant, H P Surprenant, L A Dauphinais, R E Jensen.   

Abstract

The metal backings of acetabular components can reduce the available polyethylene thickness, often to an alarming extent. This study indicated that the pitting and cracking of thin polyethylene surfaces have some similarities to tibial and patellar bearings and that creep-related deformation occurred more frequently in thin polyethylene components. Additionally, it appears that dimensional tolerances of the polyethylene inserts are difficult to maintain and may result in a nonuniform fit of both the femoral head into the component and the component into its own metal backing, which can lead to component separation. It is difficult to accurately measure the changes in material and mechanical properties of polyethylene over time. An additional ramification is that flaws, such as voids in the polyethylene, cannot be attributed to problems of bulk supply, fabrication, or postmanufacturing treatment. Orthopedic device manufacturers should keep samples of each lot of polyethylene used and provide components with serial numbers so that the source, composition, and properties of the original bulk material and material "as fabricated" can be documented. This would permit researchers studying revisions or postmortem samples to determine the changes in the polyethylene over time in vivo, thus improving the understanding of this crucial material. If manufacturers were to include dimensions and tolerances of the polyethylene inserts in their product literature, accurate measurements of wear of retrieved specimens may be possible.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2245536

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  2 in total

1.  Assessment of the midflexion rotational laxity in posterior-stabilized total knee arthroplasty.

Authors:  Kazunori Hino; Tatsuhiko Kutsuna; Yoshio Oonishi; Kunihiko Watamori; Hiroshi Kiyomatsu; Yasutake Iseki; Seiji Watanabe; Yasumitsu Ishimaru; Hiromasa Miura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-31       Impact factor: 4.342

2.  Pelvic Discontinuity Caused by Acetabular Overreaming during Primary Total Hip Arthroplasty.

Authors:  Iori Takigami; Yoshiki Ito; Takashi Mizoguchi; Katsuji Shimizu
Journal:  Case Rep Orthop       Date:  2011-12-21
  2 in total