Literature DB >> 2245502

Intrathoracic current flow during transthoracic defibrillation in dogs. Transcardiac current fraction.

O C Deale1, B B Lerman.   

Abstract

To achieve transcardiac threshold current during transthoracic defibrillation, a considerably larger current must be delivered to the thorax to compensate for the shunting effect of the lungs, the thoracic cage, and other elements of the torso. This shunting effect is thus an important determinant of transthoracic defibrillation threshold and can be quantified by the transcardiac current fraction (FC, the ratio of transcardiac to transthoracic threshold currents). Previous estimates of FC have ranged from as low as 3% to as high as 45%. The purpose of of this study was to quantify both FC and the major intrathoracic current pathways. Transthoracic and intrathoracic voltages and currents were simultaneously measured during high-voltage transthoracic shocks in 20 dogs. With correction factors determined from another set of 12 dogs, these raw data were corrected to compensate for field distortion caused by the presence of the intrathoracic electrodes, and the adjusted data were fit to a resistive network model. The results showed that 82% of the transthoracic current was shunted by the thoracic cage, while 14% was shunted by the lungs. The remaining 4% (FC) is the portion that passed through the heart. There was good agreement between the two independent methods used to calculate FC. Analysis based on the model indicated that FC was 3.7%, whereas FC determined by direct measurement with calibrated electrodes was 4.2%. Therefore, the results of this study, in contrast to earlier estimates of FC, show that defibrillation in dogs is achieved by only 4% of the total transthoracic current.

Entities:  

Mesh:

Year:  1990        PMID: 2245502     DOI: 10.1161/01.res.67.6.1405

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  2 in total

1.  Rise in defibrillation threshold after postoperative cardiac remodeling in a patient with severe Ebstein's anomaly.

Authors:  Reina Bianca Tan; Charles Love; Dan Halpern; Frank Cecchin
Journal:  HeartRhythm Case Rep       Date:  2017-04-05

2.  Investigating the efficacy of chest pressure for direct current cardioversion in atrial fibrillation: a randomised control trial protocol (Pressure-AF).

Authors:  David Ferreira; Philo Mikhail; Michael McGee; Andrew Boyle; Aaron Sverdlov; Maged William; Nicholas Jackson; Malcolm Barlow; James Leitch; Nicholas Collins; Thomas Ford; Bradley Wilsmore
Journal:  Open Heart       Date:  2021-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.