Literature DB >> 22454322

Wear of ceramic-on-carbon fiber-reinforced poly-ether ether ketone hip replacements.

Claire L Brockett1, Gemma John, Sophie Williams, Zhongmin Jin, Graham H Isaac, John Fisher.   

Abstract

Total hip replacement has been a successful surgical intervention for over 50 years, with the majority of bearings using a polyethylene cup. Long-term failure due to osteolysis and loosening has been widely documented and alternative bearings have been sought. A novel carbon fiber-reinforced poly-ether ether ketone (CFR-PEEK) cup was investigated through experimental friction and wear studies. Friction studies demonstrated the bearings operated in a boundary lubrication condition, with friction factors higher than those for other hip replacement bearings. The wear study was conducted with 36 mm diameter bearings tested against Biolox Delta heads for a period of 10 million cycles. The mean volumetric wear rate was 0.3 mm(3)/Mc, indicating the ceramic-on-CFR-PEEK bearing to be a very low wearing option for total hip replacement.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22454322     DOI: 10.1002/jbm.b.32664

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  9 in total

Review 1.  Carbon fibre reinforced PEEK versus traditional metallic implants for orthopaedic trauma surgery: A systematic review.

Authors:  Kanthan Theivendran; Faizan Arshad; Umar-Khetaab Hanif; Aleksi Reito; Xavier Griffin; Clary J Foote
Journal:  J Clin Orthop Trauma       Date:  2021-10-28

Review 2.  Polyetheretherketone (PEEK) for medical applications.

Authors:  Ivan Vladislavov Panayotov; Valérie Orti; Frédéric Cuisinier; Jacques Yachouh
Journal:  J Mater Sci Mater Med       Date:  2016-06-03       Impact factor: 3.896

Review 3.  The Use of Carbon-Fiber-Reinforced (CFR) PEEK Material in Orthopedic Implants: A Systematic Review.

Authors:  Chuan Silvia Li; Christopher Vannabouathong; Sheila Sprague; Mohit Bhandari
Journal:  Clin Med Insights Arthritis Musculoskelet Disord       Date:  2015-02-23

Review 4.  The Biologic Response to Polyetheretherketone (PEEK) Wear Particles in Total Joint Replacement: A Systematic Review.

Authors:  Ashley A Stratton-Powell; Kinga M Pasko; Claire L Brockett; Joanne L Tipper
Journal:  Clin Orthop Relat Res       Date:  2016-07-18       Impact factor: 4.176

5.  PEEK-OPTIMA as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study.

Authors:  Raelene M Cowie; Adam Briscoe; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2016-09-27       Impact factor: 1.617

6.  PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: An experimental wear study.

Authors:  Claire L Brockett; Silvia Carbone; John Fisher; Louise M Jennings
Journal:  Wear       Date:  2017-03-15       Impact factor: 3.892

7.  Third Body Wear of UHMWPE-on-PEEK-OPTIMA™.

Authors:  Raelene M Cowie; Naveen Manikya Pallem; Adam Briscoe; Louise M Jennings
Journal:  Materials (Basel)       Date:  2020-03-11       Impact factor: 3.623

Review 8.  Carbon Fiber Implants in Orthopaedic Oncology.

Authors:  Caleb M Yeung; Abhiram R Bhashyam; Shalin S Patel; Eduardo Ortiz-Cruz; Santiago A Lozano-Calderón
Journal:  J Clin Med       Date:  2022-08-24       Impact factor: 4.964

9.  Influence of contact pressure, cross-shear and counterface material on the wear of PEEK and CFR-PEEK for orthopaedic applications.

Authors:  C L Brockett; S Carbone; A Abdelgaied; J Fisher; L M Jennings
Journal:  J Mech Behav Biomed Mater       Date:  2016-06-11
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.