Literature DB >> 22454106

A nonelutable low-molecular weight heparin stent coating for improved thromboresistance.

Jonathon Zhao1, Robert Falotico, Thai Nguyen, Yan Cheng, Theodore Parker, Vipul Davé, Campbell Rogers, Johan Riesenfeld.   

Abstract

Low-molecular weight heparin (LMWH) has been widely used as a systemic anticoagulant during percutaneous coronary intervention. In this study, LMWH was covalently immobilized to the surface of a cobalt chromium reservoir-based sirolimus-eluting stent to create a nonelutable nanoscale coating for enhanced thromboresistance. Toludine-blue stained stents revealed uniform heparin coverage on all surfaces of the stent. Scanning electron microscopy of stent strut cross-sections showed identical coating thickness on all sides; while the thickness was determined to be 320 nm by a focus-ion beam system. Secondary ion mass spectrometry showed constant concentrations of O, N, and S atoms throughout the depth of the surface, confirming the uniformity of the heparin coating. The nonelutable nature of the coating was confirmed in a modified Factor Xa inhibition assay which showed the stent had an equivalent of 3-5 heparin units/cm(2), while no elutable heparin was detected in wash solutions. The antithrombin binding capacity of the immobilized heparin was determined to be 60-80 pmol/cm(2) in an antithrombin uptake assay. The enhanced thromboresistance of the heparin coating was demonstrated in an in-vitro bovine blood flow loop which showed minimal visual thrombus accumulation and 95% reduction in platelet deposition compared to uncoated control stents. Drug-eluting stents with such nonelutable LMWH coating would represent a significant advance in the treatment of patients with complex lesions who are at increased risk of developing stent thrombosis.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22454106     DOI: 10.1002/jbm.b.32692

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  3 in total

Review 1.  Use of electron microscopy to study platelets and thrombi.

Authors:  Maurizio Tomaiuolo; Rustem I Litvinov; John W Weisel; Timothy J Stalker
Journal:  Platelets       Date:  2020-05-18       Impact factor: 3.862

2.  The effect of Substance P/Heparin conjugated PLCL polymer coating of bioinert ePTFE vascular grafts on the recruitment of both ECs and SMCs for accelerated regeneration.

Authors:  Donghak Kim; Justin J Chung; Youngmee Jung; Soo Hyun Kim
Journal:  Sci Rep       Date:  2019-11-19       Impact factor: 4.379

3.  A Biocompatibility Study of Plasma Nanocoatings onto Cobalt Chromium L605 Alloy for Cardiovascular Stent Applications.

Authors:  Thithuha Phan; John E Jones; Meng Chen; Doug K Bowles; William P Fay; Qingsong Yu
Journal:  Materials (Basel)       Date:  2022-08-29       Impact factor: 3.748

  3 in total