Literature DB >> 22453838

Closure of interatrial defects by immediate-release patch.

Aliakbar Zeinaloo1, Keyhan Sayadpour Zanjani, Bahman Rastkar, Alimohammad Hajizeinali, Bahram Sohrabi, Mahmoud Samadi, Eleftherios B Sideris.   

Abstract

The Immediate-Release Patch is the newest version of the Transcatheter Patch, which is a bioabsorbable device for the closure of cardiac defects. Closure of 12 atrial septal defects and 1 fenestration was attempted using this device. Of the 13 devices used, 12 were implanted successfully (including that for the fenestration), whereas 1 device moved from the original position and was retrieved percutaneously. No other major adverse events occurred. After a median follow-up period of 11 months, trivial (≤ 2-mm) residual shunts remained in two patients, and a significant residual defect (7 mm) remained in 1 patient. The major advantages of this device include its wirelessness, its bioabsorbablity, potential application for defects up to 30 mm using only three sizes, its easier retrieval, and its ability to occlude defects with a deficient rim and some ostium primum and sinus venosus type defects. In contrast to the metal devices, it is bulkier and has a different application method requiring operator familiarity, and it sometimes leaves residual shunts.

Entities:  

Mesh:

Year:  2012        PMID: 22453838     DOI: 10.1007/s00246-012-0284-x

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  21 in total

1.  Transcatheter patch occlusion of experimental atrial septal defects.

Authors:  Eleftherios B Sideris; Chrysoula E Sideris; Stamatis F Stamatelopoulos; Spyridon D Moulopoulos
Journal:  Catheter Cardiovasc Interv       Date:  2002-11       Impact factor: 2.692

2.  The immediate release patch in the correction of experimental atrial septal defects.

Authors:  Basilios Sideris; Eleftherios Sideris; Marco Calachanis; Vasilios Papantoniou; Spiridon Moulopoulos
Journal:  Catheter Cardiovasc Interv       Date:  2010-10-01       Impact factor: 2.692

3.  Complications of transcatheter closure of atrial septal defects.

Authors:  M S Spence; S A Qureshi
Journal:  Heart       Date:  2005-08-23       Impact factor: 5.994

4.  Late erosion of an Amplatzer septal occluder device 6 years after placement.

Authors:  Nathaniel W Taggart; Joseph A Dearani; Donald J Hagler
Journal:  J Thorac Cardiovasc Surg       Date:  2011-04-03       Impact factor: 5.209

5.  Transcatheter patch occlusion of ventricular septal defect in Down syndrome.

Authors:  Aliakbar Zeinaloo; Benjamine Macuil; Keyhan Sayadpour Zanjani; Eleftherios Sideris
Journal:  Am J Cardiol       Date:  2011-04-08       Impact factor: 2.778

Review 6.  Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder.

Authors:  Abhay Divekar; Tidimogo Gaamangwe; Nasir Shaikh; Michael Raabe; John Ducas
Journal:  J Am Coll Cardiol       Date:  2005-04-19       Impact factor: 24.094

7.  Transcatheter patch correction of secundum atrial septal defects.

Authors:  Eleftherios B Sideris; Savvas Toumanides; Benjamin Macuil; Hugo Gutierrez-Leonard; Manolis Poursanov; Alexander Sokolov; Spyridon D Moulopoulos
Journal:  Am J Cardiol       Date:  2002-05-01       Impact factor: 2.778

8.  Nitinol wire mesh fracture and traumatic left atrial thrombus in a patient with atrial septal defect amplatzer occluder.

Authors:  Gholam Reza Rezaian; Ahmad Ali Amirghofran; Sasan Afifi; Ali Reza Moaref; Sheema Rezaian
Journal:  J Card Surg       Date:  2010-08-27       Impact factor: 1.620

9.  Metal allergy to Amplatzer occluder device presented as severe bronchospasm.

Authors:  Reza A Khodaverdian; Kent W Jones
Journal:  Ann Thorac Surg       Date:  2009-12       Impact factor: 4.330

10.  Embolization and retrieval of the Amplatzer septal occluder.

Authors:  Daniel S Levi; John W Moore
Journal:  Catheter Cardiovasc Interv       Date:  2004-04       Impact factor: 2.692

View more
  2 in total

1.  Further follow-up of the patient with large residual shunt after atrial septal defect closure by immediate-release patch.

Authors:  Keyhan Sayadpour Zanjani; Eleftherios B Sideris
Journal:  Pediatr Cardiol       Date:  2013-06-13       Impact factor: 1.655

Review 2.  The Future of Paediatric Heart Interventions: Where Will We Be in 2030?

Authors:  Tomohito Kogure; Shakeel A Qureshi
Journal:  Curr Cardiol Rep       Date:  2020-10-09       Impact factor: 2.931

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.