Literature DB >> 22453542

Pseudoaneurysm following percutaneous balloon angioplasty for aortic arch recoarctation after the Norwood procedure.

Katsuhiro Yamanaka1, Naoki Yoshimura, Tomonori Higuma, Fukiko Ichida.   

Abstract

We experienced a rare case of 5-month-old male infant presenting with a pseudoaneurysm following percutaneous balloon angioplasty for aortic arch recoarctation after undergoing the Norwood procedure. The pseudoaneurysm, which measured 1 cm in diameter, was located between the left carotid artery and the left subclavian artery. Under deep hypothermic circulatory arrest, resection of the pseudoaneurysm and reconstruction of the neoaortic arch were performed successfully.

Entities:  

Mesh:

Year:  2012        PMID: 22453542     DOI: 10.1007/s11748-011-0813-1

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  6 in total

1.  Impact of re-coarctation following the Norwood operation on survival in the balloon angioplasty era.

Authors:  Ilana Zeltser; Jondavid Menteer; J William Gaynor; Thomas L Spray; Bernard J Clark; Jacqueline Kreutzer; Jonathan J Rome
Journal:  J Am Coll Cardiol       Date:  2005-06-07       Impact factor: 24.094

2.  Recurrent coarctation: is surgical repair of recurrent coarctation of the aorta safe and effective?

Authors:  John W Brown; Mark Ruzmetov; Mark H Hoyer; Mark D Rodefeld; Mark W Turrentine
Journal:  Ann Thorac Surg       Date:  2009-12       Impact factor: 4.330

3.  Factors affecting long-term risk of aortic arch recoarctation after the Norwood procedure.

Authors:  Traci M Ashcraft; Karen Jones; William L Border; Pirooz Eghtesady; Jeffrey M Pearl; Phillip R Khoury; Peter B Manning
Journal:  Ann Thorac Surg       Date:  2008-04       Impact factor: 4.330

4.  Anterograde stent implantation for treatment of recurrent coarctation after Norwood operation.

Authors:  Rainer Schaeffler; Samir Sarikouch; Matthias Peuster
Journal:  Pediatr Cardiol       Date:  2007-11-20       Impact factor: 1.655

5.  Long-term (up to 20 years) results of percutaneous balloon angioplasty of recurrent aortic coarctation without use of stents.

Authors:  Oleg Reich; Petr Tax; Helena Bartáková; Viktor Tomek; Jirí Gilík; Jirí Lisy; Jirí Radvansky; Tomás Matejka; Tomás Tláskal; Irena Svobodová; Václav Chaloupecky; Jan Skovránek
Journal:  Eur Heart J       Date:  2008-06-10       Impact factor: 29.983

6.  Transluminal balloon coarctation angioplasty: experience with 27 patients.

Authors:  Z A Lababidi; D A Daskalopoulos; H Stoeckle
Journal:  Am J Cardiol       Date:  1984-12-01       Impact factor: 2.778

  6 in total