Literature DB >> 22451262

On the uncertainties of photon mass energy-absorption coefficients and their ratios for radiation dosimetry.

Pedro Andreo1, David T Burns, Francesc Salvat.   

Abstract

A systematic analysis of the available data has been carried out for mass energy-absorption coefficients and their ratios for air, graphite and water for photon energies between 1 keV and 2 MeV, using representative kilovoltage x-ray spectra for mammography and diagnostic radiology below 100 kV, and for ¹⁹²Ir and ⁶⁰Co gamma-ray spectra. The aim of this work was to establish 'an envelope of uncertainty' based on the spread of the available data. Type A uncertainties were determined from the results of Monte Carlo (MC) calculations with the PENELOPE and EGSnrc systems, yielding mean values for µ(en)/ρ with a given statistical standard uncertainty. Type B estimates were based on two groupings. The first grouping consisted of MC calculations based on a similar implementation but using different data and/or approximations. The second grouping was formed by various datasets, obtained by different authors or methods using the same or different basic data, and with different implementations (analytical, MC-based, or a combination of the two); these datasets were the compilations of NIST, Hubbell, Johns-Cunningham, Attix and Higgins, plus MC calculations with PENELOPE and EGSnrc. The combined standard uncertainty, u(c), for the µ(en)/ρ values for the mammography x-ray spectra is 2.5%, decreasing gradually to 1.6% for kilovoltage x-ray spectra up to 100 kV. For ⁶⁰Co and ¹⁹²Ir, u(c) is approximately 0.1%. The Type B uncertainty analysis for the ratios of µ(en)/ρ values includes four methods of analysis and concludes that for the present data the assumption that the data interval represents 95% confidence limits is a good compromise. For the mammography x-ray spectra, the combined standard uncertainties of (µ(en)/ρ)(graphite,air) and (µ(en)/ρ)(graphite,water) are 1.5%, and 0.5% for (µ(en)/ρ)(water,air), decreasing gradually down to u(c) = 0.1% for the three µ(en)/ρ ratios for the gamma-ray spectra. The present estimates are shown to coincide well with those of Hubbell (1977 Rad. Res. 70 58-81), except for the lowest energy range (radiodiagnostic) where it is concluded that current databases and their systematic analysis represent an improvement over the older Hubbell estimations. The results for (µ(en)/ρ)(graphite,air) for the gamma-ray dosimetry range are moderately higher than those of Seltzer and Bergstrom (2005 private communication).

Entities:  

Mesh:

Year:  2012        PMID: 22451262     DOI: 10.1088/0031-9155/57/8/2117

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Consistency checks of results from a Monte Carlo code intercomparison for emitted electron spectra and energy deposition around a single gold nanoparticle irradiated by X-rays.

Authors:  H Rabus; W B Li; H Nettelbeck; J Schuemann; C Villagrasa; M Beuve; S Di Maria; B Heide; A P Klapproth; F Poignant; R Qiu; B Rudek
Journal:  Radiat Meas       Date:  2021-07-30       Impact factor: 1.743

2.  Dosimetric investigation of a new high dose rate 192Ir brachytherapy source, IRAsource, by Monte Carlo method.

Authors:  Atefeh Rostami; Mahdi Hoseini; Mahdi Ghorbani; Courtney Knaup
Journal:  Rep Pract Oncol Radiother       Date:  2019-12-26

3.  Intercomparison of Monte Carlo calculated dose enhancement ratios for gold nanoparticles irradiated by X-rays: Assessing the uncertainty and correct methodology for extended beams.

Authors:  H Rabus; W B Li; C Villagrasa; J Schuemann; P A Hepperle; L de la Fuente Rosales; M Beuve; S Di Maria; A P Klapproth; C Y Li; F Poignant; B Rudek; H Nettelbeck
Journal:  Phys Med       Date:  2021-03-23       Impact factor: 2.685

4.  New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design.

Authors:  Evaggelos Pantelis; Panagiotis Papagiannis; Giorgos Anagnostopoulos; Dimos Baltas
Journal:  J Contemp Brachytherapy       Date:  2013-12-21

5.  Dosimetry and radioprotection evaluations of very high energy electron beams.

Authors:  Thongchai A M Masilela; Rachel Delorme; Yolanda Prezado
Journal:  Sci Rep       Date:  2021-10-12       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.