Literature DB >> 22447805

Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS randomized trials.

Giulio G Stefanini1, Robert A Byrne, Patrick W Serruys, Antoinette de Waha, Bernhard Meier, Steffen Massberg, Peter Jüni, Albert Schömig, Stephan Windecker, Adnan Kastrati.   

Abstract

AIMS: The efficacy of durable polymer drug-eluting stents (DES) is delivered at the expense of delayed healing of the stented vessel. Biodegradable polymer DES aim to avoid this shortcoming and may potentially improve long-term clinical outcomes, with benefit expected to accrue over time. We sought to compare long-term outcomes in patients treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES). METHODS AND
RESULTS: We pooled individual patient data from three large-scale multicentre randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4, and LEADERS) comparing biodegradable polymer DES with durable polymer SES and assessed clinical outcomes during follow-up through 4 years. The efficacy endpoint of interest was target lesion revascularization and the safety endpoint of interest was definite stent thrombosis. Out of 4062 patients included in the present analysis, 2358 were randomly assigned to treatment with biodegradable polymer DES (sirolimus-eluting, n= 1501; biolimus-eluting, n= 857) and 1704 patients to durable polymer SES. No heterogeneity across the trials was observed in analyses of the primary and secondary endpoints. At 4 years, the risk of target lesion revascularization was significantly lower among patients treated with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.82, 95% CI 0.68-0.98, P= 0.029). In addition, the risk of stent thrombosis was significantly reduced with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.56, 95% CI 0.35-0.90, P= 0.015), driven by a lower risk of very late stent thrombosis (hazard ratio 0.22, 95% CI 0.08-0.61, P= 0.004). In keeping with this, in landmark analysis between 1 and 4 years, the incidence of myocardial infarction was lower for patients treated with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.59, 95% CI 0.73-0.95, P= 0.031).
CONCLUSION: Biodegradable polymer DES improve safety and efficacy compared with durable polymer SES during long-term follow-up to 4 years.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22447805     DOI: 10.1093/eurheartj/ehs086

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  83 in total

1.  Three-year efficacy and safety of new- versus early-generation drug-eluting stents for unprotected left main coronary artery disease insights from the ISAR-LEFT MAIN and ISAR-LEFT MAIN 2 trials.

Authors:  Salvatore Cassese; Sebastian Kufner; Erion Xhepa; Robert A Byrne; Johanna Kreutzer; Tareq Ibrahim; Klaus Tiroch; Marco Valgimigli; Ralph Tölg; Massimiliano Fusaro; Heribert Schunkert; Karl-Ludwig Laugwitz; Julinda Mehilli; Adnan Kastrati
Journal:  Clin Res Cardiol       Date:  2015-12-22       Impact factor: 5.460

2.  Coronary stenting: A matter of revascularization.

Authors:  Aldo Bonaventura; Fabrizio Montecucco; Luca Liberale
Journal:  World J Cardiol       Date:  2017-03-26

3.  Percutaneous coronary intervention, a historical perspective looking to the future.

Authors:  Johan Bennett; Christophe Dubois
Journal:  J Thorac Dis       Date:  2013-06       Impact factor: 2.895

4.  Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography.

Authors:  Tomohisa Tada; Adnan Kastrati; Robert A Byrne; Tibor Schuster; Rezarta Cuni; Lamin A King; Salvatore Cassese; Michael Joner; Jürgen Pache; Steffen Massberg; Albert Schömig; Julinda Mehilli
Journal:  Int J Cardiovasc Imaging       Date:  2014-01-23       Impact factor: 2.357

5.  Preclinical study of a biodegradable polymer-based stent with abluminal sirolimus release.

Authors:  Celso Kiyochi Takimura; Carlos Augusto Homem M Campos; Pedro Henrique Magualhães Craveiro Melo; Julliana Carvalho Campos; Paulo Sampaio Gutierrez; Thiago Francisco Costa Borges; Luciano Curado; Spero Penha Morato; Francisco Rafael Martins Laurindo; Pedro Alves Lemos Neto
Journal:  Arq Bras Cardiol       Date:  2014-04-17       Impact factor: 2.000

Review 6.  Surgical versus percutaneous revascularization in patients with multivessel coronary artery disease.

Authors:  Piroze M Davierwala; Freidrich W Mohr
Journal:  Curr Atheroscler Rep       Date:  2014-12       Impact factor: 5.113

Review 7.  PCI and CABG surgery in 2014: CABG surgery versus PCI in CAD--surgery strikes again!

Authors:  Gennaro Giustino; Roxana Mehran
Journal:  Nat Rev Cardiol       Date:  2015-01-06       Impact factor: 32.419

Review 8.  Causes, assessment, and treatment of stent thrombosis--intravascular imaging insights.

Authors:  Daniel S Ong; Ik-Kyung Jang
Journal:  Nat Rev Cardiol       Date:  2015-03-17       Impact factor: 32.419

9.  Stent thrombosis: current management and outcomes.

Authors:  Per Sommer; Ehrin J Armstrong
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-03

Review 10.  Optimal revascularization for complex coronary artery disease.

Authors:  Javaid Iqbal; Patrick W Serruys; David P Taggart
Journal:  Nat Rev Cardiol       Date:  2013-09-17       Impact factor: 32.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.