Literature DB >> 22447053

Effects of different types of adhesive systems on the microleakage of compomer restorations in Class V cavities prepared by Er,Cr:YSGG laser in primary teeth.

Ozgul Baygin1, Fatih Mehmet Korkmaz, Ipek Arslan.   

Abstract

The aim of this in vitro study was to evaluate the effects of different types of adhesive systems on the microleakage of compomer restorations in Class V cavities prepared by erbium, chromium: yttrium scandium gallium garnet (Er,Cr:YSGG) laser. There were five test groups according to the type of adhesive applied to the cavities: Adper Single Bond 2 (Group 1), Scotchbond Multi-Purpose Plus (Group 2), Xeno III (Group 3), Clearfil Protect Bond (Group 4), Prime&Bond NT (Group 5). Dye penetration was evaluated under a stereomicroscope, and data were statistically analyzed by Kruskal-Wallis and Wilcoxon Signed Ranks tests. Gingival margins showed significantly higher microleakage than occlusal margins in all the test groups (p<0.05). Groups 1 and 2 showed significantly less microleakage than Group 5 (p<0.05), and there were no statistically significant differences among Groups 3, 4, and 5 (p>0.05). None of the dentin bonding agents eliminated microleakage completely, and higher microleakage scores were observed along the gingival margin than the occlusal margin.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22447053     DOI: 10.4012/dmj.2011-133

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  6 in total

1.  Assessment of Microleakage of a Composite Resin Restoration in Primary Teeth Following Class III Cavity Preparation Using Er, Cr: YSGG laser: An In Vitro Study.

Authors:  Priya Subramaniam; Annu Pandey
Journal:  J Lasers Med Sci       Date:  2016-07-18

2.  Evaluation of Microleakage with Total Etch, Self Etch and Universal Adhesive Systems in Class V Restorations: An In vitro Study.

Authors:  Anjali Gupta; Pradeep Tavane; Pankaj Kumar Gupta; Bellam Tejolatha; Ashik Ali Lakhani; Ram Tiwari; Shruti Kashyap; Gaurav Garg
Journal:  J Clin Diagn Res       Date:  2017-04-01

3.  An In Vitro Study of Effect of Beveling of Enamel on Microleakage and Shear Bond Strength of Adhesive Systems in Primary and Permanent Teeth.

Authors:  Shagun Patanjali; Anshul Arora; Ashtha Arya; Mandeep S Grewal
Journal:  Int J Clin Pediatr Dent       Date:  2019 May-Jun

4.  Comparison of marginal microleakage of flowable composite restorations in primary canine teeth prepared with high-speed diamond bur, Er:YAG laser and Er,Cr:YSGG laser.

Authors:  Beheshteh Malekafzali; Mohammad Asnaashari; Fateme Javadi
Journal:  Laser Ther       Date:  2017-09-30

5.  Assessment of Tooth Preparation via Er:YAG Laser and Bur on Microleakage of Dentin Adhesives.

Authors:  Zahra Bahrololoomi; Elham Heydari
Journal:  J Dent (Tehran)       Date:  2014-03-31

6.  The effects of cavity disinfection on the nanoleakage of compomer restorations: an in vitro study.

Authors:  Ipek Arslan; Ozgul Baygin; Tamer Tuzuner; Fatih Erdemir; Aykut Canakci; Fatih Mehmet Korkmaz
Journal:  Eur Oral Res       Date:  2020-01-01
  6 in total