Literature DB >> 22446841

Multimodality correlations of patellar height measurement on X-ray, CT, and MRI.

Pearlene P Lee1, Majid Chalian, John A Carrino, John Eng, Avneesh Chhabra.   

Abstract

PURPOSE: To investigate whether the universally accepted range of normal patellar height ratios derived from radiography for the Insall-Salvati (IS) and Blackburne-Peel (BP) methods could be similarly applied to both CT and MRI.
MATERIALS AND METHODS: Institutional review board approval was obtained with waiver of informed consent for this HIPPA-compliant study. A total of 45 knees in 42 patients (15 men, 27 women; age range 11 to 75 years, mean age 39 ± 20 years) who underwent tri-modality (radiograph, CT, and MRI) examinations were selected. All patients had knee imaging obtained for a variety of reasons and measurements were performed by two independent readers who were blinded to each other's measurements or the respective measurements derived from each of the methods. Paired t test was used to compare the mean values among the modalities. Inter-observer and inter-method agreements were assessed using intra-class correlation coefficients.
RESULTS: Statistically significant, but small quantitative differences are noted between tri-modality patellar height ratios. For comparable results, the small addition of 0.13 and 0.10 are needed for the Insall-Salvati measurements on MRI and CT respectively, compared with radiographs. For the Blackburne-Peel ratio, an additional adjustment of 0.09 is needed between radiographs and MRI, but not between radiographs and CT. These adjustments are independent of gender. The interobserver reproducibility was excellent (ICC ≥ 0.94) for both the Insall-Salvati and Blackburne-Peel methods for all modalities.
CONCLUSION: The results indicate that cut-off values for patella alta and baja derived from radiographs should not be directly transposed to CT and MRI; however, the adjustments are relatively minor. These measurements show excellent reproducibility for all modalities currently used for patellar height measurements.

Entities:  

Mesh:

Year:  2012        PMID: 22446841     DOI: 10.1007/s00256-012-1396-3

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  15 in total

1.  Patellar tendon length--the factor in patellar instability?

Authors:  Ph Neyret; A H N Robinson; B Le Coultre; C Lapra; P Chambat
Journal:  Knee       Date:  2002-02       Impact factor: 2.199

Review 2.  The measurement of patellar height: a review of the methods of imaging.

Authors:  C L Phillips; D A T Silver; P J Schranz; V Mandalia
Journal:  J Bone Joint Surg Br       Date:  2010-08

3.  Patella alta: association with patellofemoral alignment and changes in contact area during weight-bearing.

Authors:  Samuel R Ward; Michael R Terk; Christopher M Powers
Journal:  J Bone Joint Surg Am       Date:  2007-08       Impact factor: 5.284

4.  Interobserver variation in the measurement of patellar height after total knee arthroplasty.

Authors:  B A Rogers; P Thornton-Bott; S R Cannon; T W R Briggs
Journal:  J Bone Joint Surg Br       Date:  2006-04

Review 5.  The reliability and validity of radiological assessment for patellar instability. A systematic review and meta-analysis.

Authors:  Toby O Smith; Leigh Davies; Andoni P Toms; Caroline B Hing; Simon T Donell
Journal:  Skeletal Radiol       Date:  2010-05-23       Impact factor: 2.199

Review 6.  Intraclass correlations: uses in assessing rater reliability.

Authors:  P E Shrout; J L Fleiss
Journal:  Psychol Bull       Date:  1979-03       Impact factor: 17.737

7.  Patellar height ratios. A comparison of four measurement methods.

Authors:  E E Berg; S L Mason; M J Lucas
Journal:  Am J Sports Med       Date:  1996 Mar-Apr       Impact factor: 6.202

8.  Is patellar height really lower after high tibial osteotomy?

Authors:  H Miura; H Kawamura; R Nagamine; K Urabe; Y Iwamoto
Journal:  Fukuoka Igaku Zasshi       Date:  1997-06

9.  Reliability and interobserver variability in radiological patellar height ratios.

Authors:  R Seil; B Müller; T Georg; D Kohn; S Rupp
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2000       Impact factor: 4.342

10.  MRI criteria for patella alta and baja.

Authors:  Nogah Shabshin; Mark E Schweitzer; William B Morrison; Laurence Parker
Journal:  Skeletal Radiol       Date:  2004-06-24       Impact factor: 2.199

View more
  15 in total

1.  The reliability of four widely used patellar height ratios.

Authors:  Dennis van Duijvenbode; Michel Stavenuiter; Bart Burger; Cees van Dijke; Jacco Spermon; Marco Hoozemans
Journal:  Int Orthop       Date:  2015-07-16       Impact factor: 3.075

2.  Comparative US-MRI evaluation of the Insall-Salvati index.

Authors:  Francesco Giovagnorio; Matteo Olive; Alice Casinelli; Elena Maggini; Cristina Presicci; Celijeta Tominaj; Paolo Ricci
Journal:  Radiol Med       Date:  2017-06-29       Impact factor: 3.469

3.  A ganglion of the patellar tendon in patellar tendon-lateral femoral condyle friction syndrome.

Authors:  Sébastien Touraine; Matthieu Lagadec; David Petrover; Idan Genah; Caroline Parlier-Cuau; Valérie Bousson; Jean-Denis Laredo
Journal:  Skeletal Radiol       Date:  2013-05-09       Impact factor: 2.199

4.  Tibio-femoral and patello-femoral joint kinematics during navigated total knee arthroplasty with patellar resurfacing.

Authors:  C Belvedere; A Ensini; A Leardini; V Dedda; A Feliciangeli; F Cenni; A Timoncini; P Barbadoro; S Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-10       Impact factor: 4.342

5.  Magnetic resonance imaging-based morphological and alignment assessment of the patellofemoral joint and its relationship to proximal patellar tendinopathy.

Authors:  Michel D Crema; Larissa G Cortinas; Giovanni B P Lima; Rene Jorge Abdalla; Sheila Jean McNeill Ingham; Abdalla Y Skaf
Journal:  Skeletal Radiol       Date:  2017-12-05       Impact factor: 2.199

6.  Patella alta and patellar subluxation might lead to early failure with inlay patello-femoral joint arthroplasty.

Authors:  J Beckmann; C Merz; J Huth; B Rath; C Schnurr; E Thienpont
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-05-21       Impact factor: 4.342

7.  Patellar height measurements: Insall-Salvati ratio is most reliable method.

Authors:  Fleur V Verhulst; Jordy D P van Sambeeck; Geerte S Olthuis; Jasper van der Ree; Sander Koëter
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-05-14       Impact factor: 4.342

8.  Magnetic resonance imaging overestimates patellar height compared with radiographs.

Authors:  Juan Pablo Martinez-Cano; Riccardo Gomes Gobbi; Pedro Nogueira Giglio; Elizabeth Arendt; Giovanna Babikian Costa; Betina B Hinckel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-03-31       Impact factor: 4.114

9.  Does Patella Tendon Tenodesis Improve Tibial Tubercle Distalization in Treating Patella Alta? A Computational Study.

Authors:  Li Yin; Tzu-Chieh Liao; Liu Yang; Christopher M Powers
Journal:  Clin Orthop Relat Res       Date:  2016-08-30       Impact factor: 4.176

10.  High and Varied Anterior Condyle of the Distal Femur Is Associated with Limited Flexion in Varus Knee Osteoarthritis.

Authors:  Kohei Nishitani; Takayuki Ito; Ryosuke Hatada; Shinichi Kuriyama; Shinichiro Nakamura; Hiromu Ito; Shuicih Matsuda
Journal:  Cartilage       Date:  2020-06-04       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.