Evaluation of a 4th generation rapid HIV test for earlier and reliable detection of HIV infection in pregnancy.

Vani Chetty1, Dhayendre Moodley, Anil Chuturgoon.   

Abstract

BACKGROUND: Currently used 3rd generation rapid HIV-tests in resource-limited settings do not detect acute HIV-infections (AHI). They are known to detect HIV-infections after or late in the "window period". Detecting incident-HIV infections early in pregnancy increases opportunities for initiating antiretroviral prophylaxis to prevent mother-to-child transmission of HIV.
OBJECTIVES: We evaluated the Determine(®) HIV1/2 Ag/Ab Combo Rapid Test (Combo RT), a 4th generation test against two 3rd generation tests (SENSA-HIV1/2/0 Tri-line, SD-Bioline) for early detection of HIV-infection in pregnancy. STUDY
DESIGN: In a cohort study, plasma samples from 32 pregnant women who seroconverted at a subsequent antenatal visit (incident-infection), samples from 189 women who tested HIV positive at baseline (established-infections) and samples from 32 women remaining HIV-seronegative at a subsequent antenatal visit were tested with 3rd generation (antibody detection only) and 4th generation (antibody/antigen detection) rapid HIV tests. The HIV-1 NucliSENSEasyQ(®) v2.0 PCR test was used to quantify HIV-viral copies in women with incident HIV-infections.
RESULTS: Eighteen of 32 (56.3%) women (incident-infections) had detectable viral copies (baseline); 16 (88.9%) were antibody reactive with the Combo RT. None of the 32 specimens were reactive on the antigen component of the Combo RT. The sensitivity and specificity of the Combo RT in detecting HIV infections prior to seroconversion is 59.4% (95%CI 40.6-76.3) and 96.9% (95%CI 83.8-99.9) respectively. The Combo RT detected 94.0% of all HIV-infections if used as a screening test (baseline) compared to 85.5% detected by 3rd generation tests.
CONCLUSIONS: The Combo RT does not identify AHI but is superior to 3rd generation tests in detecting HIV antibody responses.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22445263     DOI: 10.1016/j.jcv.2012.02.021

Source DB:  PubMed          Journal:  J Clin Virol        ISSN: 1386-6532            Impact factor:   3.168


  14 in total

1.  The fourth generation AlereTM HIV Combo rapid test improves detection of acute infection in MTN-003 (VOICE) samples.

Authors:  Edward Livant; Amy Heaps; Cliff Kelly; Rashika Maharaj; Natasha Samsunder; Lindiwe Nhlangulela; Patrick Karugaba; Ravindre Panchia; Jeanne Marrazzo; Zvavahera Mike Chirenje; Urvi M Parikh
Journal:  J Clin Virol       Date:  2017-06-29       Impact factor: 3.168

2.  Poor performance of the determine HIV-1/2 Ag/Ab combo fourth-generation rapid test for detection of acute infections in a National Household Survey in Swaziland.

Authors:  Yen T Duong; Yvonne Mavengere; Hetal Patel; Carole Moore; Julius Manjengwa; Dumile Sibandze; Christopher Rasberry; Charmaine Mlambo; Zhi Li; Lynda Emel; Naomi Bock; Jan Moore; Rejoice Nkambule; Jessica Justman; Jason Reed; George Bicego; Dennis L Ellenberger; John N Nkengasong; Bharat S Parekh
Journal:  J Clin Microbiol       Date:  2014-08-13       Impact factor: 5.948

Review 3.  How can we better identify early HIV infections?

Authors:  Nora E Rosenberg; Christopher D Pilcher; Michael P Busch; Myron S Cohen
Journal:  Curr Opin HIV AIDS       Date:  2015-01       Impact factor: 4.283

Review 4.  Development and hemocompatibility testing of nitric oxide releasing polymers using a rabbit model of thrombogenicity.

Authors:  Terry C Major; Hitesh Handa; Gail M Annich; Robert H Bartlett
Journal:  J Biomater Appl       Date:  2014-06-16       Impact factor: 2.646

Review 5.  The detection and management of early HIV infection: a clinical and public health emergency.

Authors:  M Kumi Smith; Sarah E Rutstein; Kimberly A Powers; Sarah Fidler; William C Miller; Joseph J Eron; Myron S Cohen
Journal:  J Acquir Immune Defic Syndr       Date:  2013-07       Impact factor: 3.731

Review 6.  p24 revisited: a landscape review of antigen detection for early HIV diagnosis.

Authors:  Eleanor R Gray; Robert Bain; Olivia Varsaneux; Rosanna W Peeling; Molly M Stevens; Rachel A McKendry
Journal:  AIDS       Date:  2018-09-24       Impact factor: 4.177

7.  Detection of Acute HIV-1 Infection by RT-LAMP.

Authors:  Donna L Rudolph; Vickie Sullivan; S Michele Owen; Kelly A Curtis
Journal:  PLoS One       Date:  2015-05-20       Impact factor: 3.240

Review 8.  Tracking the progress of HIV: the impact of point-of-care tests on antiretroviral therapy.

Authors:  Steven D Reid; Sarah J Fidler; Graham S Cooke
Journal:  Clin Epidemiol       Date:  2013-09-26       Impact factor: 4.790

9.  Multi-centre evaluation of the Determine HIV Combo assay when used for point of care testing in a high risk clinic-based population.

Authors:  Damian P Conway; Martin Holt; Anna McNulty; Deborah L Couldwell; Don E Smith; Stephen C Davies; Philip Cunningham; Phillip Keen; Rebecca Guy
Journal:  PLoS One       Date:  2014-04-08       Impact factor: 3.240

Review 10.  Field accuracy of fourth-generation rapid diagnostic tests for acute HIV-1: a systematic review.

Authors:  Joseph M Lewis; Peter Macpherson; Emily R Adams; Eleanor Ochodo; Anita Sands; Miriam Taegtmeyer
Journal:  AIDS       Date:  2015-11-28       Impact factor: 4.177

View more