Literature DB >> 22445239

Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.

Tullio Palmerini1, Giuseppe Biondi-Zoccai, Diego Della Riva, Christoph Stettler, Diego Sangiorgi, Fabrizio D'Ascenzo, Takeshi Kimura, Carlo Briguori, Manel Sabatè, Hyo-Soo Kim, Antoinette De Waha, Elvin Kedhi, Pieter C Smits, Christoph Kaiser, Gennaro Sardella, Antonino Marullo, Ajay J Kirtane, Martin B Leon, Gregg W Stone.   

Abstract

BACKGROUND: The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents.
METHODS: For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted.
FINDINGS: 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare-metal stents at 2-year follow-up.
INTERPRETATION: In randomised studies completed to date, CoCr-EES has the lowest rate of stent thrombosis within 2 years of implantation. The finding that CoCr-EES also reduced stent thrombosis compared with bare-metal stents, if confirmed in future randomised trials, represents a paradigm shift. FUNDING: The Cardiovascular Research Foundation.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22445239     DOI: 10.1016/S0140-6736(12)60324-9

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  179 in total

Review 1.  Late stent thrombosis: the last remaining obstacle in coronary interventional therapy.

Authors:  Piera Capranzano; George Dangas
Journal:  Curr Cardiol Rep       Date:  2012-08       Impact factor: 2.931

2.  Clinical outcome after percutaneous treatment of de novo coronary bifurcation lesions using first or second generation of drug-eluting stents.

Authors:  Miroslaw Ferenc; Heinz Joachim Buettner; Michael Gick; Thomas Comberg; Juergen Rothe; Firas Khoury; Christian Valina; Aurel Toma; Piotr Kuebler; Florian Riede; Franz-Josef Neumann
Journal:  Clin Res Cardiol       Date:  2015-09-02       Impact factor: 5.460

3.  Dual Antiplatelet Therapy Duration Following Coronary Stenting. [Corrected].

Authors:  Robert W Yeh; Laura Mauri; Dean J Kereiakes
Journal:  J Am Coll Cardiol       Date:  2015-03-03       Impact factor: 24.094

4.  Blood Pressure Levels at the Time of Percutaneous Coronary Revascularization and Risk of Coronary In-Stent Restenosis.

Authors:  Giuliano Tocci; Emanuele Barbato; Roberta Coluccia; Anna Modestino; Beniamino Pagliaro; Vittoria Mastromarino; Francesca Giovannelli; Andrea Berni; Massimo Volpe
Journal:  Am J Hypertens       Date:  2015-08-13       Impact factor: 2.689

5.  The efficacy of everolimus-eluting stent implantation in patients with ST-segment elevation myocardial infarction: outcomes of 2-year clinical follow-up.

Authors:  Hideki Yano; Shigeo Horinaka; Mayuko Ishikawa; Toshihiko Ishimitsu
Journal:  Heart Vessels       Date:  2015-12-19       Impact factor: 2.037

Review 6.  Coronary stent choice in patients with acute myocardial infarction.

Authors:  Giulio G Stefanini; Stephan Windecker
Journal:  Curr Cardiol Rep       Date:  2012-08       Impact factor: 2.931

7.  Long-Term Safety and Efficacy of Platinum Chromium Everolimus-Eluting Stents in Coronary Artery Disease: 5-Year Results From the PLATINUM Trial.

Authors:  Christopher R Kelly; Paul S Teirstein; Ian T Meredith; Bruno Farah; Christophe L Dubois; Robert L Feldman; Joseph Dens; Nobuhisa Hagiwara; Abram Rabinowitz; Didier Carrié; Vincent Pompili; Alain Bouchard; Shigeru Saito; Dominic J Allocco; Keith D Dawkins; Gregg W Stone
Journal:  JACC Cardiovasc Interv       Date:  2017-12-11       Impact factor: 11.195

Review 8.  Optimal revascularization for complex coronary artery disease.

Authors:  Javaid Iqbal; Patrick W Serruys; David P Taggart
Journal:  Nat Rev Cardiol       Date:  2013-09-17       Impact factor: 32.419

9.  Network meta-analysis of randomized clinical trials: reporting the proper summaries.

Authors:  Jing Zhang; Bradley P Carlin; James D Neaton; Guoxing G Soon; Lei Nie; Robert Kane; Beth A Virnig; Haitao Chu
Journal:  Clin Trials       Date:  2013-10-03       Impact factor: 2.486

10.  Real-world antithrombotic therapies and clinical outcomes after second-generation drug-eluting stent implantation in patients with atrial fibrillation: a multi-center cohort study.

Authors:  Hisao Otsuki; Junichi Yamaguchi; Kazuho Kamishima; Hiroyuki Arashi; Nobuhisa Hagiwara
Journal:  Heart Vessels       Date:  2018-03-16       Impact factor: 2.037

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.