Literature DB >> 22444573

Cadmium (II) imprinted 3-mercaptopropyltrimethoxysilane coated stir bar for selective extraction of trace cadmium from environmental water samples followed by inductively coupled plasma mass spectrometry detection.

Nan Zhang1, Bin Hu.   

Abstract

Cd(II) imprinted 3-mercaptopropyltrimethoxysilane (MPTS)-silica coated stir bar was prepared by sol-gel technique combining with a double-imprinting concept for the first time and was employed for stir bar sorptive extraction (SBSE) of trace Cd(II) from water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. A tetramethoxysilane (TMOS) coating was first in situ created on the glass bar surface. Afterward, a sol solution containing MPTS as the functional precursor, ethanol as the solvent and both Cd(II) and surfactant micelles (cetyltrimethylammonium bromide, CTAB) as the template was again coated on the TMOS bar. The structures of the stir bar coating were characterized by FT-IR spectroscopy. Round-bottom vial was used for the extraction of Cd(II) by SBSE to avoid abrasion of stir bar coatings. The factors affecting the extraction of Cd(II) by SBSE such as pH, stirring rate and time, sample/elution volume and interfering ions have been investigated in detail, and the optimized experimental parameters were obtained. Under the optimized conditions, the adsorption capacities of non-imprinted and imprinted coating stir bars were found to be 0.5 μg and 0.8 μg bar(-1). The detection limit (3σ) based on three times standard deviations of the method blanks by 7 replicates was 4.40 ng L(-1) and the relative standard deviation (RSD) was 3.38% (c=1 μg L(-1), n=7). The proposed method was successfully applied for the analysis of trace Cd(II) in rain water, East Lake and Yangtze River water. To validate the proposed method, certified reference material of GSBZ 50009-88 environmental water was analyzed and the determined value is in a good agreement with the certified value. The developed method is rapid, selective, sensitive and applicable for the analysis of trace Cd(II) in environmental water samples.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22444573     DOI: 10.1016/j.aca.2012.02.027

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

Review 1.  Carbon-based sorbents and their nanocomposites for the enrichment of heavy metal ions: a review.

Authors:  Beshare Hashemi; Shahabaldin Rezania
Journal:  Mikrochim Acta       Date:  2019-07-26       Impact factor: 5.833

2.  In-site and solvent-free exfoliation of porous graphene oxide from pencil lead fiber for solid-phase microextraction of cadmium ion before GF-AAS determination.

Authors:  Yuan Yang; Yao Lin; Yurong Deng; Xiandeng Hou; Lu Yang; Chengbin Zheng
Journal:  Mikrochim Acta       Date:  2021-04-23       Impact factor: 5.833

3.  A simple fluorescent probe for detection of Ag+ and Cd2+ and its Cd2+ complex for sequential recognition of S2.

Authors:  Shengling Li; Duanlin Cao; Wenbing Ma; Zhiyong Hu; Xianjiao Meng; Zhichun Li; Changchun Yuan; Tao Zhou; Xinghua Han
Journal:  RSC Adv       Date:  2020-05-14       Impact factor: 4.036

4.  Twist-assisted high sensitivity chiral fiber sensor for Cd2+ concentration detection.

Authors:  Boyao Li; Aoyan Zhang; Lu Peng; Jinghua Sun; Guiyao Zhou
Journal:  iScience       Date:  2022-09-29
  4 in total