Literature DB >> 22444513

Functional protease assay using liquid crystals as a signal reporter.

Chih-Hsin Chen1, Kun-Lin Yang2.   

Abstract

We report a functional protease assay in which liquid crystals (LCs) are used as signal reporters to transduce the test results into optical signals. In this assay, an oligopeptide substrate (CLSELDDRADALQAGASQFESSAAKLKRKYWWKNLK) is used as a probe. This oligopeptide can be cleaved by α-chymotrypsin at multiple locations and become smaller fragments after the cleavage. When the original oligopeptide is immobilized on a solid surface, its long flexible oligopeptide chain is able to influence the orientation of a thin layer of LC supported on the surface, as is evident as a bright spot on the surface. In contrast, when the shorter oligopeptide fragments are immobilized on the same surface, their shorter, less flexible chains cannot disrupt the orientation of LC, and a dark spot is observed. On the basis of the dark or bright signal from LC, α-chymotrypsin in buffer solution or complex media such as chicken broth can be detected by using the naked eye. However, when the incubation time is 3h, the limit of detection (LOD) for α-chymotrypsin in buffer solution is 50 ng/mL, whereas that in chicken broth is only 500 ng/mL. Unlike traditional antibody-based assays which show little difference between active and inactive α-chymotrypsin, only active protease can be detected in this assay. This study shows the potential utility of LCs for detecting functional proteases with good specificity and sensitivity.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22444513     DOI: 10.1016/j.bios.2012.02.042

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Immunoassays for the cancer biomarker CA125 based on a large-birefringence nematic liquid-crystal mixture.

Authors:  Shih-Hung Sun; Mon-Juan Lee; Yun-Han Lee; Wei Lee; Xiaolong Song; Chao-Yuan Chen
Journal:  Biomed Opt Express       Date:  2014-12-23       Impact factor: 3.732

2.  Using Diazotization Reaction to Develop Portable Liquid-Crystal-Based Sensors for Nitrite Detection.

Authors:  Tsung Yang Ho; Yi-Hsuan Lan; Jhih-Wei Huang; Jung-Jung Chang; Chih-Hsin Chen
Journal:  ACS Omega       Date:  2020-05-08

3.  Selective Ligand-Doped Liquid Crystal-Based Sensing Platform for Detection of ClO- Ions in Aqueous Media.

Authors:  Farid Moeinpour; Fatemeh S Mohseni-Shahri; Asma Verdian; Elham Sheikhzadeh
Journal:  ACS Omega       Date:  2022-10-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.