Literature DB >> 22443461

Improving xylem hydraulic conductivity measurements by correcting the error caused by passive water uptake.

José M Torres-Ruiz1, John S Sperry, José E Fernández.   

Abstract

Xylem hydraulic conductivity (K) is typically defined as K = F/(P/L), where F is the flow rate through a xylem segment associated with an applied pressure gradient (P/L) along the segment. This definition assumes a linear flow-pressure relationship with a flow intercept (F(0)) of zero. While linearity is typically the case, there is often a non-zero F(0) that persists in the absence of leaks or evaporation and is caused by passive uptake of water by the sample. In this study, we determined the consequences of failing to account for non-zero F(0) for both K measurements and the use of K to estimate the vulnerability to xylem cavitation. We generated vulnerability curves for olive root samples (Olea europaea) by the centrifuge technique, measuring a maximally accurate reference K(ref) as the slope of a four-point F vs P/L relationship. The K(ref) was compared with three more rapid ways of estimating K. When F(0) was assumed to be zero, K was significantly under-estimated (average of -81.4 ± 4.7%), especially when K(ref) was low. Vulnerability curves derived from these under-estimated K values overestimated the vulnerability to cavitation. When non-zero F(0) was taken into account, whether it was measured or estimated, more accurate K values (relative to K(ref)) were obtained, and vulnerability curves indicated greater resistance to cavitation. We recommend accounting for non-zero F(0) for obtaining accurate estimates of K and cavitation resistance in hydraulic studies.
Copyright © Physiologia Plantarum 2012.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22443461     DOI: 10.1111/j.1399-3054.2012.01619.x

Source DB:  PubMed          Journal:  Physiol Plant        ISSN: 0031-9317            Impact factor:   4.500


  6 in total

1.  Studies on the tempo of bubble formation in recently cavitated vessels: a model to predict the pressure of air bubbles.

Authors:  Yujie Wang; Ruihua Pan; Melvin T Tyree
Journal:  Plant Physiol       Date:  2015-04-23       Impact factor: 8.340

2.  Stem Hydraulic Conductivity depends on the Pressure at Which It Is Measured and How This Dependence Can Be Used to Assess the Tempo of Bubble Pressurization in Recently Cavitated Vessels.

Authors:  Yujie Wang; Jinyu Liu; Melvin T Tyree
Journal:  Plant Physiol       Date:  2015-10-14       Impact factor: 8.340

3.  Noninvasive Measurement of Vulnerability to Drought-Induced Embolism by X-Ray Microtomography.

Authors:  Brendan Choat; Eric Badel; Regis Burlett; Sylvain Delzon; Herve Cochard; Steven Jansen
Journal:  Plant Physiol       Date:  2015-11-02       Impact factor: 8.340

4.  Seawater exposure causes hydraulic damage in dying Sitka-spruce trees.

Authors:  Hongxia Zhang; Xinrong Li; Wenzhi Wang; Alexandria L Pivovaroff; Weibin Li; Peipei Zhang; Nicholas D Ward; Allison Myers-Pigg; Henry D Adams; Riley Leff; Anzhi Wang; Fenghui Yuan; Jiabing Wu; Steve Yabusaki; Scott Waichler; Vanessa L Bailey; Dexin Guan; Nate G McDowell
Journal:  Plant Physiol       Date:  2021-10-05       Impact factor: 8.005

5.  Drought will not leave your glass empty: Low risk of hydraulic failure revealed by long-term drought observations in world's top wine regions.

Authors:  Guillaume Charrier; Sylvain Delzon; Jean-Christophe Domec; Li Zhang; Chloe E L Delmas; Isabelle Merlin; Deborah Corso; Andrew King; Hernan Ojeda; Nathalie Ollat; Jorge A Prieto; Thibaut Scholach; Paul Skinner; Cornelis van Leeuwen; Gregory A Gambetta
Journal:  Sci Adv       Date:  2018-01-31       Impact factor: 14.136

6.  Controversies in Midday Water Potential Regulation and Stomatal Behavior Might Result From the Environment, Genotype, and/or Rootstock: Evidence From Carménère and Syrah Grapevine Varieties.

Authors:  Luis Villalobos-González; Mariana Muñoz-Araya; Nicolas Franck; Claudio Pastenes
Journal:  Front Plant Sci       Date:  2019-12-02       Impact factor: 5.753

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.