Accuracy of paramedic Broselow tape use in the prehospital setting.

Theodore Heyming1, Nichole Bosson, Aileen Kurobe, Amy H Kaji, Marianne Gausche-Hill.   

Abstract

BACKGROUND: The Broselow tape is widely used to rapidly estimate weight and facilitate proper medication dosing in pediatric patients.
OBJECTIVE: We aimed to determine the accuracy of prehospital use of the Broselow tape.
METHODS: We prospectively enrolled a consecutive sample of pediatric patients transported to the emergency department (ED) at Harbor-UCLA Medical Center from February 2008 to January 2009. Eligible subjects arrived via ambulance and were less than 145 cm tall, the upper limit of height for Broselow measurements. Subjects were excluded if they had a medical condition preventing proper measurement (e.g., contractures). Per Los Angeles County protocol, paramedics obtained a Broselow weight on all pediatric patients. The paramedic Broselow weight was compared with the ED Broselow weight and the ED scale weight, which was obtained unless mobilization was contraindicated. Accuracy was determined by assessing Bland-Altman plots and the Pearson correlation coefficient. As part of a sensitivity analysis, multiple imputation was used to account for missing data.
RESULTS: There were 572 subjects enrolled. The median age was 24 months (interquartile range [IQR] 10 to 49 months); 316 (55%) of the subjects were male. The weighted Cohen's kappa assessing agreement between the paramedic and ED Broselow colors was 0.74 (95% confidence interval [CI] 0.68 to 0.79). The median difference between the paramedic Broselow weight and the scale weight was -0.10 kg (IQR -1.7 to 0.7). The accuracy of the paramedic Broselow weight when compared with the ED scale weight and the ED Broselow weight as defined by Pearson's correlation coefficient was 0.92 (95% CI 0.90 to 0.93) and 0.97 (95% CI 0.97 to 0.98), respectively. Multiple imputation for missing data did not alter the results.
CONCLUSION: Paramedic Broselow weight correlates well with scale weight and ED Broselow weight. Paramedics can use the Broselow tape to accurately determine weight for pediatric patients in the prehospital setting.

Entities:  

Mesh:

Year:  2012        PMID: 22443376     DOI: 10.3109/10903127.2012.664247

Source DB:  PubMed          Journal:  Prehosp Emerg Care        ISSN: 1090-3127            Impact factor:   3.077


  9 in total

1.  The RAMA Ped Card: Does it work for actual weight estimation in child patients at the emergency department.

Authors:  Thavinee Trainarongsakul; Pitsucha Sanguanwit; Supawan Rojcharoenchai; Kittisak Sawanyawisuth; Yuwares Sittichanbuncha
Journal:  World J Emerg Med       Date:  2017

Review 2.  [New pediatric drug dosage aids. Improving patient safety].

Authors:  J M Strauß
Journal:  Med Klin Intensivmed Notfmed       Date:  2015-10-12       Impact factor: 0.840

3.  Comparison of Errors Using Two Length-Based Tape Systems for Prehospital Care in Children.

Authors:  Lara D Rappaport; Lina Brou; Tim Givens; Maria Mandt; Ashley Balakas; Kelley Roswell; Jason Kotas; Kathleen M Adelgais
Journal:  Prehosp Emerg Care       Date:  2016-02-02       Impact factor: 3.077

4.  Accuracy of estimation of total body weight by legs and head weight measuring and comparison method in the anesthetized patients.

Authors:  Ebrahim Nasiri; Reza Nasiri
Journal:  Anesth Essays Res       Date:  2013 Sep-Dec

Review 5.  The accuracy of emergency weight estimation systems in children-a systematic review and meta-analysis.

Authors:  Mike Wells; Lara Nicole Goldstein; Alison Bentley
Journal:  Int J Emerg Med       Date:  2017-09-21

6.  Are "virtual" paediatric weight estimation studies valid?

Authors:  Mike Wells; Lara Goldstein
Journal:  Afr J Emerg Med       Date:  2019-01-17

7.  Weighty Matters: A Real-World Comparison of the Handtevy and Broselow Methods of Prehospital Weight Estimation.

Authors:  Chloe Knudsen-Robbins; Phung K Pham; Kim Zaky; Shelley Brukman; Carl Schultz; Claus Hecht; Kellie Bacon; Maxwell Wickens; Theodore Heyming
Journal:  Prehosp Disaster Med       Date:  2022-10       Impact factor: 2.866

8.  Pediatric Tape: Accuracy and Medication Delivery in the National Park Service.

Authors:  Danielle D Campagne; Megann Young; Jedediah Wheeler; Geoff Stroh
Journal:  West J Emerg Med       Date:  2015-10-20

9.  The accuracy of Broselow pediatric emergency tape in estimating body weight of pediatric patients.

Authors:  Amal H ALSulaibikh; Fahad I Al-Ojyan; Khalid N Al-Mulhim; Thabit S Alotaibi; Faisal O Alqurashi; Latifa F Almoaibed; Mohye H ALwahhas; Mohammad A ALjumaan
Journal:  Saudi Med J       Date:  2017-08       Impact factor: 1.484

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.