Literature DB >> 22442780

Horizontal and vertical dimensional changes of peri-implant facial bone following immediate placement and provisionalization of maxillary anterior single implants: a 1-year cone beam computed tomography study.

Phillip Roe1, Joseph Y K Kan, Kitichai Rungcharassaeng, Joseph M Caruso, Grenith Zimmerman, Juan Mesquida.   

Abstract

PURPOSE: This cone beam computed tomography study (CBCT) evaluated horizontal and vertical dimensional changes to the facial bone following maxillary anterior single immediate implant placement and provisionalization.
MATERIALS AND METHODS: CBCT scans taken immediately after (T1) and 1 year after surgery (T2) were evaluated. The midsagittal cut of each implant was identified, and measurements were made at predetermined levels. Horizontal facial bone thickness (HFBT) was measured at 0, 1, 2, 4, 6, 9, and 12 mm apical to the implant platform. Vertical facial bone level (VFBL) was the perpendicular distance from the implant platform (0) to the most coronal point of the facial bone. Measurements were recorded and changes between T1 and T2 were calculated. The data were analyzed statistically at a significance level of α = 0.05.
RESULTS: CBCT scans of 21 patients were analyzed. At T2, the mean HFBT changes ranged from -1.23 to -0.08 mm at the seven different levels evaluated. The mean VFBL change was -0.82 mm. The HFBT changes at the 1- to 9-mm levels were not significantly different from one another, but they were significantly smaller than the change at the 0-mm level and significantly greater than the change at the 12-mm level. Significant positive correlations were observed only between horizontal and vertical changes and between horizontal change and initial VFBL at the implant platform. While the VFBL of eight implants (38%) was apical to the implant platform at T2, none was noted at T1.
CONCLUSIONS: Dimensional changes to the peri-implant facial bone following maxillary anterior single immediate implant placement and provisionalization should be expected. The greatest HFBT change was noted at the implant platform level, in part because HFBT change is correlated to the initial VFBL and the change in VFBL at that level.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22442780

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  13 in total

1.  Long-term stability of early implant placement with contour augmentation.

Authors:  D Buser; V Chappuis; U Kuchler; M M Bornstein; J G Wittneben; R Buser; Y Cavusoglu; U C Belser
Journal:  J Dent Res       Date:  2013-10-24       Impact factor: 6.116

2.  [Clinical evaluation of the socket-shield technique for immediate implantation in the maxillary anterior region].

Authors:  Sheng-Jie Yan; Cong Zhou; Jin Liu; Xiang-Na Xu; Yun Yang; Xin Chen; Jing Lan
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2019-12-01

3.  Ridge alterations post-extraction in the esthetic zone: a 3D analysis with CBCT.

Authors:  V Chappuis; O Engel; M Reyes; K Shahim; L-P Nolte; D Buser
Journal:  J Dent Res       Date:  2013-10-24       Impact factor: 6.116

4.  Marginal Bone Level and Bone Thickness Reduction in Delayed and Immediate Implant Placement Protocol 6 Months Post-loading: An Observational Clinical Prospective Study.

Authors:  Maroun Dagher; Nadim Mokbel; Rami Aboukhalil; Nabil Ghosn; Abdelrahman Kassir; Nada Naaman
Journal:  J Maxillofac Oral Surg       Date:  2022-01-07

5.  Distally Tilted Implants According to the All-on-Four® Treatment Concept for the Rehabilitation of Complete Edentulism: A 3.5-Year Retrospective Radiographic Study of Clinical Outcomes and Marginal Bone Level Changes.

Authors:  Árpád László Szabó; Ádám László Nagy; Csaba Lászlófy; Márió Gajdács; Péter Bencsik; Krisztina Kárpáti; Zoltán Baráth
Journal:  Dent J (Basel)       Date:  2022-05-11

6.  Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region.

Authors:  Kirsten W Slagter; Gerry M Raghoebar; Arjan Vissink; Henny J A Meijer
Journal:  Int J Implant Dent       Date:  2015-04-18

7.  Thickness of the buccal bone wall and root angulation in the maxilla and mandible: an approach to cone beam computed tomography.

Authors:  P López-Jarana; C M Díaz-Castro; A Falcão; C Falcão; J V Ríos-Santos; M Herrero-Climent
Journal:  BMC Oral Health       Date:  2018-11-21       Impact factor: 2.757

8.  Effect of Flapless Immediate Implantation and Filling the Buccal Gap with Xenograft Material on the Buccal Bone Level: A Randomized Clinical Trial.

Authors:  Mojgan Paknejad; Solmaz Akbari; Hoori Aslroosta; Mehrdad Panjnoush; Samira Hajheidary
Journal:  J Dent (Tehran)       Date:  2017-11

9.  Height difference between the vestibular and palatal walls and palatal width: a cone beam computed tomography approach.

Authors:  P López-Jarana; C M Díaz-Castro; A Falcão; C Falcão; J V Ríos-Santos; A Fernández-Palacín; M Herrero-Climent
Journal:  BMC Oral Health       Date:  2021-03-15       Impact factor: 2.757

10.  CBCT analysis of the tissue thickness at immediate implant placement with contour augmentation in the maxillary anterior zone: a 1-year prospective clinical study.

Authors:  Yuya Fujita; Tamaki Nakano; Shinji Ono; Takuya Shimomoto; Keiichiro Mizuno; Hirofumi Yatani; Shoichi Ishigaki
Journal:  Int J Implant Dent       Date:  2021-07-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.