Literature DB >> 22441324

Minimal detectable change of knee extension force measurements obtained by handheld dynamometry from older patients in 2 settings.

Richard W Bohannon1.   

Abstract

BACKGROUND AND
PURPOSE: The measurement properties of handheld dynamometry (HHD) have been studied extensively, but information about the responsiveness of the procedure is scant. The purpose of this study, therefore, was to determine the responsiveness (minimal detectable change [MDC]) for measurements of knee extension force obtained by HHD from older adult patients in 2 different settings.
METHODS: This study involved the retrospective retrieval of knee extension force data of the left and right sides from 2 sources (acute rehabilitation [n = 53] and home care [n = 46]). The standard deviation of the forces and the weighted mean intraclass correlation coefficient (ICC) from 3 previous studies (ICC = 0.90) were then used to calculate the MDC95%.
RESULTS: The MDC95% ranged from 46.0 to 79.0 N. It was lower for patients measured in a home care setting than for those measured in an acute rehabilitation setting. DISCUSSION AND
CONCLUSIONS: By describing the MDC for knee extension force obtained by HHD from older adults in 2 settings, this study provides an indication of the changes in force that would have to be surpassed to conclude that a real change in knee extension strength was observed. The MDCs reported have a role in the interpretation of repeated measurements and in setting goals for changes in knee extension force.

Entities:  

Mesh:

Year:  2012        PMID: 22441324     DOI: 10.1519/JPT.0b013e3182239f64

Source DB:  PubMed          Journal:  J Geriatr Phys Ther        ISSN: 1539-8412            Impact factor:   3.381


  3 in total

1.  Reliability of a Test for Assessment of Isometric Trunk Muscle Strength in Elderly Women.

Authors:  Marceli M A Mesquita; Marta S Santos; Alan B S Vasconcelos; Clodoaldo A de Sá; Luana C D Pereira; Ínea B M da Silva-Santos; Walderi M da Silva Junior; Dihogo G de Matos; Alan Dos S Fontes; Paulo M P Oliveira; Felipe J Aidar; Josimari M DeSantana; Iohanna G S Fernandes; Marzo E Da Silva-Grigoletto
Journal:  J Aging Res       Date:  2019-07-01

2.  Reliability, minimal detectable change and measurement errors in knee extension muscle strength measurement using a hand-held dynamometer in young children.

Authors:  Koji Shigeshima; Hiroshi Yamasaki; Kunihiro Katayama
Journal:  J Phys Ther Sci       Date:  2022-09-01

3.  Experimental Approach of Quadriceps Strength Measurement: Implications for Assessments in Critically Ill Survivors.

Authors:  Anne-Françoise Rousseau; Isabelle Kellens; Pierre Delanaye; Olivier Bruyère; Benoit Misset; Jean-Louis Croisier
Journal:  Diagnostics (Basel)       Date:  2022-01-14
  3 in total