Different manufacturers of syringes: a new source of variability in blood gas, acid-base balance and related laboratory test?

Gabriel Lima-Oliveira1, Giuseppe Lippi, Gian Luca Salvagno, Martina Montagnana, Geraldo Picheth, Gian Cesare Guidi.   

Abstract

OBJECTIVE: Evaluate whether four different brands/types of heparin coated syringes can represent a source of variability in blood gas analysis (BGA). DESIGN AND METHODS: Blood was collected from one hundred volunteers into different syringes: Syringe I (lithium heparin and calcium balanced); Syringe II: in-house prepared (sodium heparin); Syringe III: (spray-dried calcium-balanced lithium heparin); Syringe IV (lyophilized electrolyte-balanced lithium heparin).
RESULTS: Significant differences were as follows: a) Syringe I vs II: pO(2), sO(2), pCO(2)(t), cHCO(3)(-), ctCO(2), base excess (BE), total hemoglobin (tHb), sodium (Na(+)), potassium (K(+)), calcium (Ca(2+)), glucose (Glu), lactate (Lac), O(2) Hb and p 50; b) Syringe I vs III: pH, pO(2), cHCO(3)(-), ctCO(2), BE, Na(+), Glu, Lac and p 50; c) Syringe I vs IV: pH, pO(2), sO(2), pCO(2)(t), BE, Na(+), K(+), Ca(2+), Glu, Lac and O(2) Hb; d) Syringe II vs III: pH, pO(2), sO(2), pCO(2)(t), cHCO(3)(-), ctCO(2), ctO(2), tHb, Na(+), K(+), Ca(2+), Lac and p 50; e) Syringe II vs IV: pH, pO(2), sO(2), pCO(2)(t), cHCO(3)(-), ctCO(2), BE, tHb, Na(+), K(+), Ca(2+), Lac, O(2) Hb and p 50; f) Syringe III vs IV: pH, pO(2), sO(2), cHCO(3)(-), ctCO(2), ctO(2), BE, Na(+), K(+), Ca(2+), O(2) Hb and p 50.
CONCLUSION: The different manufacturers of syringes can represent new source of variability on BGA.
Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22440459     DOI: 10.1016/j.clinbiochem.2012.03.007

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  13 in total

1.  A new device to relieve venipuncture pain can affect haematology test results.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Marise Danielle Raulino Campelo; Katharyne Soares Adala Tajra; Flavio dos Santos Gomes; Carlos David Valentim; Sylvio José Colonna Romano; Geraldo Picheth; Gian Cesare Guidi
Journal:  Blood Transfus       Date:  2013-07-18       Impact factor: 3.443

2.  Quality impact on diagnostic blood specimen collection using a new device to relieve venipuncture pain.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Indian J Clin Biochem       Date:  2013-04-03

3.  Concordance between point-of-care blood gas analysis and laboratory autoanalyzer in measurement of hemoglobin and electrolytes in critically ill patients.

Authors:  Shivesh Prakash; Shailesh Bihari; Zhan Y Lim; Santosh Verghese; Hemant Kulkarni; Andrew D Bersten
Journal:  J Clin Lab Anal       Date:  2018-03-03       Impact factor: 2.352

4.  Use of liquid heparin for blood gas sampling in pediatric intensive care unit: A comparative study of effects of varying volumes of heparin on blood gas parameters.

Authors:  Viswas Chhapola; Sandeep Kumar; Pallavi Goyal; Rajni Sharma
Journal:  Indian J Crit Care Med       Date:  2013-11

5.  K(3)EDTA Vacuum Tubes Validation for Routine Hematological Testing.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Giovanni Poli; Giovanni Pietro Solero; Geraldo Picheth; Gian Cesare Guidi
Journal:  ISRN Hematol       Date:  2012-07-24

6.  Use of a blood gas analyzer and a laboratory autoanalyzer in routine practice to measure electrolytes in intensive care unit patients.

Authors:  Yasemin U Budak; Kagan Huysal; Murat Polat
Journal:  BMC Anesthesiol       Date:  2012-08-03       Impact factor: 2.217

7.  Impact of the phlebotomy training based on CLSI/NCCLS H03-a6 - procedures for the collection of diagnostic blood specimens by venipuncture.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

8.  The effective reduction of tourniquet application time after minor modification of the CLSI H03-A6 blood collection procedure.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

9.  Preanalytical management: serum vacuum tubes validation for routine clinical chemistry.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

10.  Incorrect order of draw could be mitigate the patient safety: a phlebotomy management case report.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.