Literature DB >> 22438458

The influence of measurement location on reliability of quantitative nailfold videocapillaroscopy in patients with SSc.

Andrea K Murray1, Andy Vail, Tonia L Moore, Joanne B Manning, Christopher J Taylor, Ariane L Herrick.   

Abstract

OBJECTIVES: Nailfold videocapillaroscopy is being increasingly used as a marker of SSc-related microvascular disease, including in response to treatment. However, it requires further validation. Our aim was to assess the inter-observer, intra-observer and test-retest variability of semi-automated measurement of capillary features as well as of a manual density measurement.
METHODS: All capillary apexes in images from 58 patients with SSc were marked up independently by two trained observers (inter-observer variability). The first observer then re-marked the images (intra-observer variability), and finally, the first observer marked up a second image of the same nailfold (test-retest). Mark-up of capillaries was carried out on cropped mosaic images (cropped independently by the observers to a fixed width, to allow the same length of nail bed to be studied for each patient) and on whole mosaic images (examining the whole nail bed).
RESULTS: Reproducibility of independently cropped mosaic images was poor and was due to the variation in the positioning of the cropped area. However, quantification of whole mosaic images was highly reproducible, e.g. for inter-capillary distance, the intra-class correlation coefficient for inter-observer, intra-observer and test-retest reliability was 0.95, 0.98 and 0.90 (compared with 0.88, 0.79 and 0.89 for cropped mosaic images), respectively. Intra-observer limits of agreement for whole mosaic images were better than inter-observer reproducibility.
CONCLUSION: Quantitative assessment of SSc-related change in nailfold capillaries is unreliable if examination of the same set of capillaries cannot be guaranteed. Conversely a wide-field, high-magnification system that allows visualization of the whole nail bed offers a highly reproducible approach for quantitative assessment and therefore has potential as an outcome measure.

Entities:  

Mesh:

Year:  2012        PMID: 22438458     DOI: 10.1093/rheumatology/kes007

Source DB:  PubMed          Journal:  Rheumatology (Oxford)        ISSN: 1462-0324            Impact factor:   7.580


  6 in total

1.  A Reproducible Computerized Method for Quantitation of Capillary Density using Nailfold Capillaroscopy.

Authors:  Cynthia Cheng; Chadd W Lee; Constantine Daskalakis
Journal:  J Vis Exp       Date:  2015-10-27       Impact factor: 1.355

Review 2.  Is there evidence for vasculitis in systemic sclerosis?

Authors:  Lesley Ann Saketkoo; Oliver Distler
Journal:  Curr Rheumatol Rep       Date:  2012-12       Impact factor: 4.592

Review 3.  [Capillaroscopy. An update].

Authors:  J Richter; C Iking-Konert; M Schneider; O Sander
Journal:  Z Rheumatol       Date:  2013-03       Impact factor: 1.372

Review 4.  [Capillary microscopy].

Authors:  W Hermann
Journal:  Z Rheumatol       Date:  2016-08       Impact factor: 1.372

5.  Non-invasive detection of severe neutropenia in chemotherapy patients by optical imaging of nailfold microcirculation.

Authors:  Aurélien Bourquard; Alberto Pablo-Trinidad; Ian Butterworth; Álvaro Sánchez-Ferro; Carolina Cerrato; Karem Humala; Marta Fabra Urdiola; Candice Del Rio; Betsy Valles; Jason M Tucker-Schwartz; Elizabeth S Lee; Benjamin J Vakoc; Timothy P Padera; María J Ledesma-Carbayo; Yi-Bin Chen; Ephraim P Hochberg; Martha L Gray; Carlos Castro-González
Journal:  Sci Rep       Date:  2018-03-28       Impact factor: 4.379

6.  Three-dimensional optoacoustic imaging of nailfold capillaries in systemic sclerosis and its potential for disease differentiation using deep learning.

Authors:  Suhanyaa Nitkunanantharajah; Katja Haedicke; Tonia B Moore; Joanne B Manning; Graham Dinsdale; Michael Berks; Christopher Taylor; Mark R Dickinson; Dominik Jüstel; Vasilis Ntziachristos; Ariane L Herrick; Andrea K Murray
Journal:  Sci Rep       Date:  2020-10-05       Impact factor: 4.379

  6 in total